English
Language : 

BP5062-5 Datasheet, PDF (1/3 Pages) Rohm – AC100V input, −5V/500mA output
AC/DC converter
AC100V input, −5V/500mA output
BP5062-5
Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
−190
500
2
−20 ∼ +80
−25 ∼ +105
Unit
V
mApk
kV
°C
°C
Dimension(Unit : mm)
34.5MAX.
9.9MAX.
3.3MAX
1 3 5 7 8 10 12
0.5±0.1 1.3±0.2
P=5.08±0.2
2.54×11=27.94
0.25±0.05
5.05MAX.
4.85MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi −113 −141 −170 V DC (80∼120VAC)
Output voltage
Vo −4.7 −5.0 −5.3 V Vi=−141V, Io=500mA
Output current
Line regulation
Io
0
−
500 mA Vi=−141V
∗1
Vr
− 0.05 0.2
V Vi=−113V∼ −170V, Io=500mA
Load regulation
Vl
− 0.07 0.3
V Vi=−141V, Io=0∼500mA
Output ripple voltage Vp
Power conversion effciency η
− 0.15 0.3 Vp-p Vi=−141V, Io=500mA ∗2
60 71
−
% Vi=−141V, Io=500mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Application circuit
BP5062-5
Please note that pin No.12
side is input.
12 10 8 7
D1
R1
FUSE
2A
1SR139-400 4.7Ω1/4W
Input
AC100V
50Hz/60Hz
ZNR − C1
C2
220V + 22µF/200V 0.22µF
53
L1
220µH
Pin No.
Function
1 Output terminal Vo(−5V)
2 Not used
3 Coil connect
4 Not used
5 Coil connect
6 Not used
7 COMMON
8 COMMON
9 Not used
1
10 N.C.
11 Not used
Output 12 Input terminal Vi(−141VDC)
−5V
− C3
+ 470µF/25V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Rectifier diode
L1: Choke coil
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 2A
Capacitance : 22µF∼100µF Rated voltage : 200V or higher
Ripple current is 0.22Arms above.
Especially when the capacity is enlarged, rush current at powering up is
increased. Please be careful in the evaluation.
Capacitance : 0.1µF∼0.22µF Rated voltage : 200V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 220µF∼820µF Rated voltage : 16V or higher,
ESR is 0.25Ω max. Ripple current is 0.4Arms above.
Output noise voltage is infulenced.Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 1A or higher,
and the peak surge current should be 40A or higher.
(Full-wave rectifier can be used in out part.)
The inductance should be 220µH,the rated direct current should be 1.3A
above. Otherwise heating or abnormal oscilation occurs.
When the input smoothing capacitor is enlarged,the rating of the rectifier
diode should be higher.
4.7Ω∼10Ω 1/4W
Reduce the noise terminal voltage.The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
Derating Curve
Derating Curve
600
500
400
300
Operation Range
200
100
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=−141V)
100 200 300 400 500
Output Current Io(mA)
Load Regulation
Load Regulation
(Ta=25°C, Vi=−141V)
6
5
4
3
2
1
0
0 100 200 300 400 500 600 700 800
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C, Vi=−141V)
60
50
40
30
20
10
0
0 100 200 300 400 500 600 700 800
Output Current Io(mA)
1/2