FM3104 Datasheet, PDF (12/25 Pages) List of Unclassifed Manufacturers – Integrated Processor Companion with Memory
FM3104/16/64/256
0Ch
RC
CC
C2P
C1P
0Bh
SNL
WP1-0
Event Counter Control
D7
D6
D5
D4
D3
D2
D1
D0
-
-
-
-
RC
CC
C2P
C1P
Read Counter. Setting this bit to 1 takes a snapshot of the four counters bytes allowing the system to read the
values without missing count events. The RC bit will be automatically cleared.
Counter Cascade. When CC=0, the event counters operate independently according to the edge programmed by
C1P and C2P respectively. When CC=1, the counters are cascaded to create one 32-bit counter. The registers of
Counter 2 represent the most significant 16-bits of the counter and CNT1 is the controlling input. Bit C2P is
“don’t care” when CC=1. Battery-backed, read/write.
CNT2 detects falling edges when C2P = 0, rising edges when C2P = 1. C2P is “don’t care” when CC=1. The value
of Event Counter 2 may inadvertently increment if C2P is changed. Battery-backed, read/write.
CNT1 detects falling edges when C1P = 0, rising edges when C1P = 1. The value of Event Counter 1 may
inadvertently increment if C1P is changed. Battery-backed, read/write.
Companion Control
D7
D6
D5
D4
D3
D2
D1
D0
SNL
-
-
WP1
WP0
VBC
VTP1
VTP0
Serial Number Lock. Setting to a 1 makes registers 11h to 18h and SNL permanently read-only. SNL cannot be
cleared once set to 1. Nonvolatile, read/write.
Write Protect. These bits control the write protection of the memory array. Nonvolatile, read/write.
VBC
VTP1-0
Write protect addresses WP1 WP0
None
0
0
Bottom 1/4
0
1
Bottom 1/2
1
0
Full array
1
1
VBAK Charger Control. Setting VBC to 1 causes a 15 µA trickle charge current to be supplied on VBAK.
Clearing VBC to 0 disables the charge current. Nonvolatile, read/write.
VTP select. These bits control the reset trip point for the low VDD reset function. Nonvolatile, read/write.
0Ah
WDE
WDT4-0
VTP
VTP1 VTP0
2.6V
0
0
2.9V
0
1
3.9V
1
0
4.4V
1
1
Watchdog Control
D7
D6
D5
D4
D3
D2
D1
D0
WDE
-
-
WDT4
WDT3
WDT2
WDT1
WDT0
Watchdog Enable. When WDE=1, a watchdog timer fault will cause the /RST signal to go active. When WDE = 0
the timer runs but has no effect on /RST, however the WTR flag will be set when a fault occurs. Note as the timer
is free-running, users should restart the timer using WR3-0 prior to setting WDE=1. This assures a full watchdog
timeout interval occurs. Nonvolatile, read/write.
Watchdog Timeout. Indicates the minimum watchdog timeout interval with 100 ms resolution. New watchdog
timeouts are loaded when the timer is restarted by writing the 1010b pattern to WR3-0. Nonvolatile, read/write.
Watchdog timeout
Invalid – default 100 ms
100 ms
200 ms
300... ms
2000 ms
2100 ms
220...0 ms
2900 ms
3000 ms
Disable counter
WDT4 WDT3 WDT2 WDT1 WDT0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
0
0
0
1
1
1
0
1
0
0
1
0
1
0
1
1
0
1
1
0
1
1
1
0
1
1
1
1
1
0
1
1
1
1
1
Rev. 3.2
July 2010
Page 12 of 25