English
Language : 

I9600 Datasheet, PDF (6/7 Pages) Radiometrix Ltd – 9600 baud Transparent Data Link IC
Interfacing a i9600 to a transmitter
4k7
10k
NC
TXE
JP1
Test
RXE
20.48MHz 15pF
SETUP OSC1
NC
VSS
OSC2
VDD
100Ω
15pF
NC
TXD
4k7
RSTXD
RSRXD
NC
NC 100nF
BUSY
RXD
5V
supply
RF
EN
TXD
Vcc
GND
Figure 7: i9600 interfaced to a Transmitter (e.g. TX3A)
Interfacing a i9600 to a receiver
5V supply
RF
4k7
JP1
JP2
10k
NC
Test
SETUP
NC
VSS
NC
RSTXD
RSRXD
BUSY
TXE
RXE
OSC1
OSC2
VDD
TXD
NC
NC
RXD
20.48MHz 15pF
100Ω
15pF
100nF
EN
RXD
Vcc
GND
Figure 8: i9600 interfaced to a Receiver (e.g. RX3A)
In receive mode, the RSTXD pin should be tie to the supply rail via a 10kΩ resistor and needs to be
provided with a jumper connector (JP2) as shown. This is because this input is still needed for the
programming function (activated by pulling setup low). Remove the JP2 jumper when programming.
Interfacing a i9600 to a Microcontroller
i9600 can also directly be interfaced to any microcontrollers. If the microcontroller has a built-in UART,
it can concentrate on its main task and leave the packet formatting, bit balancing and error checking of
serial data to i9600.
BUSY pin can be connected to one of the port pins which can generate an interrupt on low-to-high
transition (e.g. RB0/INT pin in the PIC). This can be used to enter a receive sub-routine to download
data received from remote i9600. Therefore, the host does not need to wait in a loop for a packet.
Range test and site survey can be carried out by connecting an LED on the BUSY pin. Every time,
i9600 is within range to receive valid data, the LED will flicker.
Ordering Information:
i9600-000-SS - Shrink Small Outline
i9600-000-SO - Small Outline
i9600-000-DIL - Plastic Dual In Package
Note: The i9600 modem ICs cannot be ordered separately. They can only be ordered with equal number of
Radiometrix radio modules.
Radiometrix Ltd
i9600 Data Sheet
page 6