English
Language : 

QPD-60-5 Datasheet, PDF (1/2 Pages) Qualtek Electronics Corporation – 60Watts Single Output
60Watts Single Output
Qualtek
Electronics Corporation
P
P C QPD-60 Series
Features:
Universal AC input/ Full range
Wide Operating Ambient Temperature (-20°C~70°C)
High Efficiency, and High Reliability
Output Protections: OLP/OVP/SCP
All using 105°C long life electrolytic capacitors.
100% full load burn-in test
Model
QPD-60-5
QPD-60-12
QPD-60-15
QPD-60-24
QPD-60-48
Output Characteristics
DC Output
5V
12V
15V
24V
48V
Rated Current
10A
5A
4A
2.5A
1.25A
Current Range
0~10A
0~5A
0~4A
0~2.5A
0~1.25A
Ripple and Noise (-20~70°C)
Voltage ADJ. Range
Voltage Accuracy
Line Regulation
Load Regulation
Set-up Time
Hold-up Time
<50mV
<50mV
<100mV
<100mV
4.6V-5.5V
11.0V-13.0V
13.7V-16.0V
22.0V-25.3V
±2.0%
±2.0%
±2.0%
±2.0%
±0.5%
±0.5%
±0.5%
±0.5%
±2.0%
±2.0%
±2.0%
±2.0%
<2.0s (115VAC input, full load); <1.0s (230VAC input, full load)
>10ms (115VAC input, full load); >20ms (230VAC input, full load)
<200mV
45.3V-51.3V
±2.0%
±0.5%
±2.0%
Temperature Coefficient
±0.03%/°C
Overshoot and Undershoot
<5.0%
Input Characteristics
Voltage Range
88VAC~264VAC, 124VDC~370VDC
Frequency Range
47Hz-63Hz
Efficiency
115VAC Input 75%
81%
81%
83%
84%
(Typical)
230VAC Input 76%
82%
82%
83%
85%
AC Current (max)
1.5A
1.5A
1.5A
1.5A
1.5A
Inrush Current (Typical)
40A@115VAC Cold start 60A@230VAC Cold start
Leakage Current
<0.25mA@115VAC <3.5mA@230VAC
Protection
Over Load (OLP)
105%~150% of rated output current, hiccup mode, auto recovery
120%~150% of rated output voltage, shut down, re-power on to recover (5V)
Over Voltage (OVP)
110%~133% of rated output voltage, shut down, re-power on to recover (12V)
110%~140% of rated output voltage, shut down, re-power on to recover (15V, 24V)
Short Circuit (SCP)
110%~125% of rated output voltage, shut down, re-power on to recover (48V)
Long-term mode, auto recovery
Environmental Characteristics
Operating Amb. Temp. & Hum
Storage Temp. & Hum
Safety Standards
-20°C~70°C; 20%~90% RH Non-Condensing
-40°C~85°C: 10%-95% RH Non-Condensing
UL60950-1; EN60950-1: 2006
Withstand Voltage
Primary-Secondary: 3.0KVAC;≤10mA. Primary-PG: 1.5KVAC;≤10mA. Secondary-PG: 0.5KVDC;≤10mA
Isolation Resistance
EMI Conduction & Radiation
EMS Immunity
≥100M ohms
Compliance to EN55022(CISPR22) Class B
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light industry level, criteria A
General Characteristics
MTBF (MIL-HDBK-217F)
Dimension (LxWxH)
Packing
Cooling Method
More than 200,000Hrs (25°C, Full load)
129x98x38mm
30PCS/CTN. G.W: 14.2kgs
Cooling by free air convection
Rev. B
Page 1 of 2