English
Language : 

PYX28C64 Datasheet, PDF (2/11 Pages) Pyramid Semiconductor Corporation – 8K x 8 EEPROM
PYX28C64
MAXIMUM RATINGS(1)
Symbol
Parameter
VCC
Power Supply Pin with
Respect to GND
V
TERM
Terminal Voltage with
Respect to GND
(up to 6.25V)
TA
Operating Temperature
Value Unit
–0.3 to +6.25 V
–0.5 to
+6.25
V
–55 to +125 °C
Symbol Parameter
TBIAS
Temperature Under
Bias
TSTG
Storage Temperature
P
Power Dissipation
T
I
DC Output Current
OUT
Value Unit
–55 to +125 °C
–65 to +150 °C
1.0
W
50
mA
RECOMMENDED OPERATING
TEMPERATURE AND SUPPLY VOLTAGE
Grade(2)
Military
Ambient
Temperature
–55°C to +125°C
GND
0V
V
CC
5.0V ± 10%
CAPACITANCES(4)
VCC = 5.0V, TA = 25°C, f = 1.0MHz
Symbol Parameter Conditions Typ. Unit
CIN
COUT
Input Capacitance
V = 0V
IN
10 pF
Output Capacitance VOUT = 0V 10 pF
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)
Symbol
Parameter
Test Conditions
VIH Input High Voltage
VIL Input Low Voltage
VHC CMOS Input High Voltage
VLC CMOS Input Low Voltage
VOL
Output Low Voltage
(TTL Load)
I = +8 mA, V = Min.
OL
CC
P5C164
Min
Max
2.0
–0.5(3)
VCC +0.3
0.8
VCC –0.2
–0.5(3)
VCC +0.5
0.2
0.4
Unit
V
V
V
V
V
VOH
Output High Voltage
(TTL Load)
IOH = –4 mA, VCC = Min.
2.4
V
ILI Input Leakage Current
ILO Output Leakage Current
ISB
Standby Power Supply
Current (TTL Input Levels)
VCC = Max.
VIN = GND to VCC
VCC = Max., CE = VIH,
VOUT = GND to VCC
CE ≥ VIH, OE = VIL,
VCC= Max,
f = Max., Outputs Open
–10
+10
µA
–10
+10
µA
___
3
mA
Standby Power Supply
I
SB1
Current
(CMOS Input Levels)
CE
≥
V,
HC
VCC= Max,
f = 0, Outputs Open
VIN ≤ VLC or VIN ≥ VHC
___
250
µA
ICC Supply Current
CE = OE =
V,
IL
WE = VIH,
All I/O's = Open,
Inputs = V = 5.5V
CC
___
60
mA
Notes:
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
periods may affect reliability.
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
3. Transient inputs with VIL and IIL not more negative than –3.0V and
–100mA, respectively, are permissible for pulse widths up to 20 ns.
4. This parameter is sampled and not 100% tested.
Document # EEPROM101 REV B
Page 2 of 11