Notes:
1. Circuit ground is internally isolated from chassis ground.
2. TFAULT is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on the host
board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V.A high output indicates a
transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds.
A low output indicates normal operation. In the low state, the output is pulled to <0.8V.
3. Laser output disabled on T >2.0V or open, enabled on T <0.8V.
DIS
DIS
4. Should be pulled up with 4.7kΩ- 10kΩ host board to a voltage between 2.0V and 3.6V. MOD_ABS pulls line low
to indicate module is plugged in.
5. Internally pulled down per SFF-8431 Rev 4.1.
6. LOS is open collector output. It should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V
and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
VI. Digital Diagnostic Functions
SFPPT-CWXX-01 transceivers support the 2-wire serial communication protocol as defined in the SFP+MSA.
The standard SFP serial ID provides access to identification information that describes the transceiver’s capabilities,
standard interfaces, manufacturer, and other information.
Additionally, SFP+ transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows
real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical
power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and
warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.
The SFP MSA defines a 256-byte memory map in EEPROM that is accessible over a 2-wire serial interface at the 8 bit
address 1010000X (A0h).The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h),
so the originally defined serial ID memory map remains unchanged.
The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller
(DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated,
the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP
transceiver into those segments of the E2PROM that are not write-protected. The negative edge clocks data from the
PART NUMBER
DFTO
SFPPT-CWxx-01
ELLA
http://www.pulseelectronics.com/
DATE
REVISION
22 Sep., 2014
P1
SHEET NO
6 OF 8