Z-400UK Electical Specifications
Matching BT impedance for voice terminals
150nF // 750⦠+ 270â¦
POTS Pass Band Return Loss
Line and Phone
port with 1 filter
0.3 - 0.5kHz
0.5 - 2.0kHz
2.0 - 3.4kHz
14dB Min
18dB Min
14dB Min
0.3 - 0.5kHz
14dB Min
Line port with 2 filter
0.5kHz
0.5 - 2.0kHz
18dB Min
16dB Min
2.0 - 3.4kHz
12dB Min
0.3 - 0.5kHz
14dB Min
Line port with 3 filter
0.5 kHz
0.5 - 2.0kHz
18dB Min
14dB Min
2.0 - 3.4kHz
10dB Min
Off-Hook Insertion Loss: Maximum IL and IL Variation
200Hz < f < 4kHz, with 1 filter
2.0dB Max
200Hz < f < 4kHz, with 2 filter
2.5dB Max
200Hz < f < 4kHz, with 3 filter
3.0dB Max
On-Hook Insertion Loss with high impedance: Maximum IL and IL Variation
200Hz < f < 2.8kHz, with 1~3 filter
4.0dB Max
On-Hook Insertion Loss with low impedance: Maximum IL and IL Variation
200Hz < f < 2.8kHz, with 1 filter
2.0dB Max
Unbalance About Earth (terminated with 600â¦)
50Hz to 600Hz
40dB Min
600Hz to 3400Hz
46dB Min
3400Hz to 4000Hz
40dB Min
Longitudinal Balance (25kHz to 1.1MHz)
40dB Min
Off-Hook ADSL Stop Band Isolation (Insertion Loss) w/100⦠at Line/Phone
32kHz to 200KHz
30dB Min
200kHz to 30MHz
55dB Min
DSL Signal Loss
32kHz to 50kHz
50kHz to 30MHz
3.0dB Max
1.0dB Max
0.2 - 0.6kHz
250us Max
Group Delay
0.6 - 3.2kHz
200us Max
3.2 - 4.0kHz
250us Max
DC Resistance
50⦠Max
Isolation impedance
5M⦠Min
Ringing voltage drop at 25Hz and 50Hz
< 2VRMS(source e.m.f. 35 VRMS)
DC Feeding Current (Loop Current)
< 80 mA
AC ringing voltage (25-50Hz)
< 100 Vrms
Connectors: UK plug (Line); RJ11 Jack (DSL); UK socket (Phone)
www.pulseelectronics.com
Z-400UK.A (3/14)
|
▷ |