T-330SCT_14 Datasheet, PDF (2/2 Pages) Pulse A Technitrol Company – Copperhead High Speed Dual Transformers
Copperhead™ High Speed
Dual Transformers
Mechanical
T-3200SCT
1.520,700MAX
.073
.350
1,86
8,89
.010
0,25
TYP
.020 ± .002
0,51 ± 0,05
T-3200SCT
Date Code
Country of Origin
.059
1,50
TYP
.280 .375
7,11
9,53
MAX
.415 .268
10,53 7,37
.235
5,97
MAX
.010
0,25
TYP
.050
1,27
TYP
.030
0,76
.050
1,27
.025
0,64
0° - 8°
Schematic
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
Weight . . . . . . . . . . . . . . .1.0 grams
Tape & Reel . . . . . . . . . . . . 600/reel
Dimensions:
Inches
mm
Unless otherwise specified,
all tolerances are ± .005
0,13
Application
Pulse Specialty Components has designed Fibre Channel
dual transformers specifically for point to point coupling
to 150 twinax cable. The isolation transformers protect the
station from static charges that may develop on the cable,
and prevents ground loop currents from being transferred
between stations. The devices have also been designed to
provide common mode rejection within the transmission
band and thus reduce EMI. The wide bandwidth of these
devices minimizes data dependent jitter by providing
fast signal rise times. Low-end bandwidth also minimizes
base-line wander, another contributor to jitter. The dual
package allows connection of both transmit and receive
channels, as shown in the application circuit below.
Surface-mount packagin also allows a cost-effective
solution.
TY
TX
330 ohm
±5%
Notes #1
330 ohm 51 ohm
±5%
± 1%
51 ohm
± 1%
T-330SCT
or
T-1062SCT
1
16
TWINAX
150 ohm
T-330SCT
or
T-1062SCT
1
16
3 1:1 14
3 1:1 14
TERMINATION
Note #2
RY
VREF
RX
RY
VREF
RX
6
11
8 1:1 9
6
11
8 1:1 9
51 ohm
± 1%
51 ohm
± 1%
330 ohm
±5%
TY
TX
TERMINATION
Note #2
Fig. 1 - Typical Application Circuit Notes #1
1. The transformer, 51 Ω resistors, and the impedance of
connector.
330 ohm
±5%
the driver are matched to achieve the best return loss
4. It is recommended that the center tap (CT) of
(S11) for the transmitter of the 150 Ω system.
2. The total impedance of termination resistor network is
transformer(s), cable side, be connected to earth/
chassis (cable shield) ground either directly or via a
150 Ω.
transient voltage suppressor (TVS) type component
3. When laying out PCB, transmission line methods must
and earth/chassis ground should be “AC-coupled” to
be utilized to maintain return loss and signal integrity.
signal (digital) ground through a 0.27uF, 500v
Transformer must be located within .50 of the DB9
capacitor.
For More Information
Pulse Worldwide
Headquarters
12220 World Trade Drive
San Diego, CA
92128
U.S.A.
Pulse Europe
Einsteinstrasse 1
D-71083 Herren-
berg
Germany
Tel: 858 674 8100
Tel: 49 7032 7806
Pulse China Headquarters
B402, Shenzhen Academy of
Aerospace Technol-
ogy Bldg.
10th Kejinan Road
High-Tech Zone
Nanshan District
Shenzen, PR China
518057
Pulse North China
Room 2704/2705
Super Ocean Finance
Ctr.
2067 Yan An Road
West
Shanghai 200336
China
Pulse South Asia
135 Joo Seng Road
#03-02
PM Industrial Bldg.
Singapore 368363
Tel: 65 6287 8998
Fax: 65 6287 8998
Pulse North Asia
3F, No. 198
Zhongyuan Road
Zhongli City
Taoyuan County 320
Taiwan R. O. C.
Tel: 886 3 4356768
Fax: 886 3 4356823
(Pulse)
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product names mentioned herein may be
trademarks or registered trademarks of their respective owners. © Copyright, 2014. Pulse Electronics, Inc. All rights reserved.
2
pulseelectronics.com
M105.E (12/14)