X-1622NL Datasheet, PDF (1/2 Pages) Pulse A Technitrol Company – GATE DRIVE TRANSFORMER | |||
|
GATE DRIVE TRANSFORMER
Military/Aerospace Grade
Storage & Operating Temperature: -55ºC to +125ºC
60 V - µsec MAX
Lead ï¬nish: SN100
MSL: 3
1500Vrms isolation (380Vrms continuous)
Part 3,4
Number
X-1622NL
Turns Ratio
1:1:1
Electrical Speci cations 25°C
Pri-Sec
Insulation
Max1
(V*µsec)
Primary Inductance
(µH MIN)
1500 VRMS
60
1800
Leakage 2
Inductance
0.60
DCR Primary
(⦠MAX)
1.60
DCR Secondary
(⦠MAX)
1.60
Notes:
1. The maximum volt-µsec rating limits the peak flux density to 2800 Gauss
when used in a unipolar drive application. For bi-polar drive applications a
maximum volt-µsec of two times this rating is acceptable (ie: 2* (volt*µsec
rating) Volt*µsec = (voltage applied to the primary) * dutycycle / Frequecy = V
* alpha / Freq_Hz = V * µsec
2. Leakage inductance is measured at primary terminals with all secondaries
shorted.
3. Optional Tape & Reel packaging can be ordered by adding a âTâ suffix to
the part number (i.e. X-1622NL becomes X-1622NLT). Pulse complies to
industry standard tape and reel specification EIA481.
4. The âNLâ suffix indicates an RoHS-compliant part number. Sn63Pb37 Lead
Finish available on request.
5. The temperature of the component (ambient plus temperature rise) must
be within the stated operating temperature range.
X-1622NL
Mechanical
Schematic
1
pulseelectronics-milaero.com
M295 (01/17)
|
▷ |