English
Language : 

PG1096.152NL Datasheet, PDF (1/3 Pages) Pulse A Technitrol Company – Round wire Coils
SMT Power Inductors
Round wire Coils– PG1096NL series
Inductance Range: 1.5uH to 82uH
Current Rating: up to 65Apk
Footprint: 26mm x 26mm Max
Height: 14.8mm Max
No Thermal Aging
RoHS Compliant
Electrical Specifications @ 25°C - Operating Temperature -40°C to 130°C1
Part Number
Inductance
@ Irated2
µH TYPICAL
Irated 3
(A)
Controlled Electrical Specs.
Saturation 5
Current Isat
(A TYP)
DCR 4
Inductance
(mΩ)
@ 0Adc 25°C 100°C
MAX
(µH ± 20%)
Heating Current 6
Idc
(A TYP)
Core Loss Factor 7
(K2)
PG1096.152NL
1.35
50
0.85
1.5
65 50.5
50
27.9
PG1096.252NL
2.25
45
1.2
2.5
55 43
45
31
PG1096.472NL
4.2
35
1.8
4.7
40 31
35
43.7
PG1096.682NL
6
30
2
6.8
35 27.5
30
50.6
PG1096.103NL
9
24.5
3.15
10
28 21.8
24.5
62
PG1096.183NL
16
18.5
5
18
21 16.5
18.5
83.6
PG1096.223NL
19.5
17
5.5
22
19 14.8
17
90.9
PG1096.333NL
29.5
13.5
10.5
33
15.5 12
13.5
111.5
PG1096.473NL
42.3
11
12.5
47
13 10
11
134.4
PG1096.683NL
61
9.5
15
68
11 8.6
9.5
168.5
PG1096.823NL
73.5
8.5
22
82
10 7.8
8.5
179.3
Notes:
1. Actual temperature of the component during system operation (ambient plus tem-
perature rise) must be within the standard operating range.
2. Inductance at Irated is a typical inductance value for the component taken at rated
current.
7.
3. The rated current as listed is either the saturation current (@ 25°C) or the heating
current depending on which value is lower.
4. The DCR of the part is measured at an ambient temperature of 20°C±3°C from point a
to b as shown below on the mechanical drawing.
5. The saturation current, Isat, is the current at which the component inductance drop by
20% (typical) at an ambient temperature. This current is determined by placing the
component in the specified ambient environment and applying a short duration pulse
current (to eliminate self-heating effect) to the component.
8.
6. The heating current, Idc, is the DC current required to raise the component tempera- 9.
ture by approximately 40°C. The heating current is determined by mounting the
component on a typical PCB and applying current for 30 minutes. The temperature is
measured by placing the thermocouple on top of the unit under test. Take note that
the components’ performance varies depending on the system condition. It is sug-
gested that the component be tested at the system level, to verify the temperature
rise of the component during system operation.
Core loss approximation is based on published core data:
Core Loss = K1 * (f)1.42 * (K2ΔI)2.57 in mW
K1=2.86E-09 (2.50E-09 FOR PG1096.152NL)
f = switching frequency in KHz
K1 & K2 = core loss factors
ΔI= delta I across the component in Ampere
K2ΔI=one half of the peak to peak flux density across the component in Gauss
Unless otherwise specified, all testing is made at 100kHz, 0.1Vac
Optional Tape & Reel packaging can be ordered by adding a “T” suffix to the part
number (i.e. PG1096.223NL becomes PG1096.223NLT). Pulse complies with industry
standard tape and reel specification EIA481. The tape and reel for this product has a
width (W=44.0mm), pitch (Po=36.0mm) and depth (Ko=15.6mm).
1
pulseelectronics.com
P745.C (03/16)