24V, 20A, DC/DC CONVERTER
6. OUTPUT
Output voltage
nom. 24V
Adjustment range
min. 24-28V
guaranteed
max. 30V****)
at clockwise end position of potentiometer
Factory settings
typ. 24.1V
±0.2%, at full load, cold unit, in “single use” mode
typ. 24.1V
±0.2%, at full load, cold unit, in “parallel use” mode
typ. 25.1V
at no load, cold unit, in “parallel use” mode
Line regulation
Load regulation
max. 10mV
max. 100mV
typ. 1000mV
88-370Vdc
in “single use” mode: static value, 0A Æ 20A;
see Fig. 6-1
in “parallel use” mode: static value, 0A Æ 20A,
see Fig. 6-2
Ripple and noise voltage
max. 70mVpp
20Hz to 20MHz, 50Ohm
Output current
nom. 20A
at 24V, ambient temperature <60°C, see Fig. 6-1
nom. 24A*)
at 24V, ambient temperature <45°C, see Fig. 6-1
nom. 17.1A
at 28V, ambient temperature <60°C, see Fig. 6-1
nom. 20.6A*)
at 28V, ambient temperature <45°C, see Fig. 6-1
typ. 80A
up to 15ms, output voltage stays above 20V, see Fig.
6-4. This peak current is available once every five
seconds. See chapter 22.1 for more peak current
measurements.
Output power
nom. 480W
continuously available
nom. 576W*)
Power Boost®*)
Overload behaviour
cont. current
output voltage > 13Vdc, see Fig. 6-1
HiccupPLUS mode**) output voltage < 13Vdc, see Fig. 6-1
Short-circuit current
min. 35A***)
load impedance <10mOhm, see Fig. 6-3
max. 45A***)
load impedance <10mOhm, see Fig. 6-3
max. 15A***)
average (R.M.S.) current, load impedance 50mOhm,
see Fig. 6-3
min. 70A
< 15ms, load impedance <10mOhm, see Fig. 6-4
typ. 100A
< 15ms, load impedance <10mOhm, see Fig. 6-4
Output capacitance
typ. 7 000μF
included inside the DC/DC converter
*)
**)
***)
****)
Power Boost
This power/ current is continuously allowed up to an ambient temperature of 45°C.
Above 45°C, do not use this power/ current longer than a duty cycle of 10% and/ or not longer than 1 minute every 10 minutes.
HiccupPLUS Mode
At heavy overloads (when output voltage falls below 13V), the DC/DC converter delivers continuous output current for 2s. After this,
the output is switched off for approx. 18s before a new start attempt is automatically performed. This cycle is repeated as long as the
overload exists. If the overload has been cleared, the device will operate normally. See Fig. 6-3.
Discharge current of output capacitors is not included.
This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not
guaranteed value which can be achieved. The typical value is about 28.5V (in “single use” mode).
Apr. 2014 / Rev. 1.3 DS-CPS20.241-D1-EN
All parameters are specified at 24V, 20A, 300Vdc, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/25