CD-Series
CD5.243
DC/DC Converter 24V, 4A
5. OUTPUT
Output voltage
Adjustment range
Factory setting
Line regulation
Load regulation
Ripple and noise voltage
Output capacitance
Output current
Output power
Short-circuit current
nom. 24V
min. 24-28V
*)
max. 30V
at clockwise end position of potentiometer
24.1V
±0.2%, at full load, cold unit
max. 25mV
max. 100mV
Input voltage variations between 8.4 to 16.2Vdc
static value, 0A Æ 4A
max. 50mVpp
20Hz to 20MHz, 50Ohm
typ. 2 200μF
nom. 4.8A
at 24V, below 45°C ambient temperature, input voltage
between 10.8V and 16.2V
nom. 4.0A
at 24V, at 60°C ambient temperature, input voltage
between 10.8V and 16.2V
nom. 3.0A
at 24V, at 70°C ambient temperature, input voltage
between 10.8V and 16.2V
nom. 4.1A
at 28V, below 45°C ambient temperature, input voltage
between 10.8V and 16.2V
nom. 3.4A
at 28V, at 60°C ambient temperature, input voltage
between 10.8V and 16.2V
nom. 2.6A
at 28V, at 70°C ambient temperature, input voltage
between 10.8V and 16.2V
Derate output current at input voltages below 10.8V according to chapter 3.
Derate linearely between +45°C and +70°C and between 10.8V and 8.4V input
voltage.
nom. 116W
for ambient temperatures < 45°C
nom. 96W
for ambient temperatures < 60°C
min. 6A
continuous current, short circuit impedance 200mOhm
max. 9A
continuous current, short circuit impedance 200mOhm
*) extended guaranteed adjustment range down to 23V.
Fig. 5-1 Output voltage vs. output current at
12Vdc input voltage, typ.
Output Voltage
28V
24
20
16
12
8
4
0
024
Adjustment
Range
Output
Current
6 8 10 12A
Fig. 5-2 Current limitation vs. input voltage,
(23V constant voltage load), typ.
Output Current
5.6A
5.5
5.4
5.3
5.2
5.1
5.0
4.9
Input Voltage
4.8
8 9 10 11 12 13 14 15 16Vdc
Mar. 2016 / Rev. 1.3 DS-CD5.243-EN
All parameters are specified at 24V, 4A, 12Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/22