English
Language : 

ML60.122 Datasheet, PDF (1/23 Pages) PULS GmbH – 12V, 4.5A, SINGLE PHASE INPUT
MiniLine-2
ML60.122
12V, 4.5A, SINGLE PHASE INPUT
POWER SUPPLY
ƒ 100-240V Wide Range Input
ƒ NEC Class 2 Compliant
ƒ Adjustable Output Voltage
ƒ Efficiency up to 87.6%
ƒ Low No-load Losses and Excellent Partial-load Efficiency
ƒ Compact Design, Width only 45mm
ƒ Electronic Inrush Current Limitation
ƒ Operation down to -40°C
ƒ Full Output Power up to +60°C
ƒ Large International Approval Package
ƒ 3 Year Warranty
GENERAL DESCRIPTION
A compact size, light weight, simple mounting onto the
DIN-rail and the utilization of only quality components
are what makes the MiniLine power supplies so easy to
use and install within seconds.
A rugged electrical and mechanical design as well as a
high immunity against electrical disturbances on the
mains provides reliable output power. This offers
superior protection for equipment which is connected
to the public mains network or is exposed to a critical
industrial environment.
The MiniLine series offers output voltages from 5 to
56Vdc and a power rating from 15W to 120W.
The specialty of the ML60.122 is the electronic inrush
current limitation and the suitability for very low
ambient temperatures. The unit is fully specified down
to -40°C.
The supplementary MiniLine decoupling diode module
MLY10.241 allows building of redundant systems or to
protect against back-feeding voltages.
SHORT-FORM DATA
Output voltage
Adjustment range
Output current
Output power
Output ripple
Input voltage
DC 12V
12 - 15V
4.5A at 12V
3.6A at 15V
54W
< 50mVpp
AC 100-240V
Mains frequency
AC Input current
Power factor
AC Inrush current
50-60Hz
0.97 / 0.61A
0.54 / 0.44
typ. 6A
DC Input
88-375Vdc
Efficiency
85.8 / 87.6%
Losses
8.9 / 7.6W
Temperature range -40°C to +70°C
Derating
1.4W/°C
Hold-up time
typ. 25 / 113ms
Dimensions
45x75x91mm
Weight
250g / 0.55lb
20Hz to 20MHz
-15% / +10%
AC 100V mains
requires derating
±6%
at 120 / 230Vac
at 120 / 230Vac
input voltage
and temperature
independent
below 130Vdc
derating required
at 120 / 230Vac
at 120 / 230Vac
operational
+60 to +70°C
at 120 / 230Vac
WxHxD
ORDER NUMBERS
Power Supply ML60.122
Accessory
MLY10.241
ZM3.WALL
12-15V Standard unit
Redundancy Module
Wall mount bracket
MARKINGS
Ind. Cont. Eq. UL 508
Class I Div 2
UL 60950-1
NEC
Class 2
Marine
EMC, LVD
Nov. 2015 / Rev. 1.4 DS--ML60.122-EN
All parameters are specified at 12V, 4.5A, 230Vac 50Hz input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
1/23