English
Language : 

FAB1204021 Datasheet, PDF (2/4 Pages) Power System Technology – Power factor correction front end for : Industrial and hard environment
SIGNALS
Valid :
(EN+ ; EN-) :
FAB1204021
Provide authorisation for the load to start up if EN+/EN- is activated and if
establisment time of the PFC is finished
enable when +12Vmig-Vvalid =12V/80mA
enable otherwise
input for load enabling
disable when < 1V
enable when > 3V
ENVIRONMENTAL
Storage temperature :
Operating temperature :
-40°C to +100°C
-40°C to +65°C, ambient external air forced 2m/s min.
Mechanical, shock, acceleration : built to meet MIL-STD-810E
EMI / EMC
MIL-STD-461E
built to meet CE101 limit Fig.CE101-4, CE102 limit Fig. CE102-1,
No laboratory certification, certified in the customer equipment.
ISOLATION
Input to Chassis :
Input to +12Vmig &Vvalid :
Input signal to primary :
Input signal to Chassis :
2121 Vdc or 1500Vrms without Y capacitor
4250 Vdc
4250 Vdc
2120Vdc
GENERAL
Safety :
built to meet EN60950
Rev. 00
2/4