SMDA03LC_11 Datasheet, PDF (7/10 Pages) Protek Devices – 500 WATT MULTI-LINE LOW CAPACITANCE TVS ARRAY
Only One Name Means ProTek’Tion™
application information
TPIN
TPIP
SMDA03LC - SMDA24LCC
8
7
6
5
TPON
1
2
3
4
TPOP
figure 2 - BIDIRECTIONAL COMMON-MODE ETHERNET PROTECTION
Circuit connectivity is as follow:
• TPIN connected to Pin 5.
• TPIP connected to Pin 6.
• TPON connected to Pin 1.
• TPOP connected to Pin 2.
• Pins 3, 4, 7 and 8 connected to ground.
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
• The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
• The path length between the TVS device and the protected line should be minimized.
• All conductive loops including power and ground loops should be minimized.
• The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
• Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.
05074.R9 9/10