LCD05C_11 Datasheet, PDF (6/8 Pages) Protek Devices – HIGH POWERED MULTI-LINE TVS ARRAY | |||
|
◁ |
Only One Name Means ProTekâTionâ¢
application information
Port 1
USB Output
D+ Connector
D- 16
15
1
2
Port 3
USB Output
Connector
D+
D- 12
11
LCD05C - LCD24C
14
USB
IC
3
10
Port 2
USB Output
Connector D+
13
D-
4
Port 4
USB Output
Connector D+
9
D-
5
6
7
8
figure 1 - COMMON-MODE USB Protection
Circuit connectivity is as follows:
⢠Pins 1, 2, 3, 4, 5, 6, 7 and 8 connected to ground.
⢠Pins 16 and 15 connected to Port 1, D- and D+.
⢠Pins 14 and 13 connected to Port 2, D- and D+.
⢠Pins 12 and 11 connected to Port 3, D- and D+.
⢠Pins 10 and 9 connected to Port 4, D- and D+.
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
⢠The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
⢠The path length between the TVS device and the protected line should be minimized.
⢠All conductive loops including power and ground loops should be minimized.
⢠The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
⢠Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.
05018.R8 11/10
Page 6