SLVU2.8-8_12 Datasheet, PDF (5/8 Pages) Protek Devices – 600 WATT MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY | |||
|
◁ |
Only One Name Means ProTekâTionâ¢
application information
Line 1
Line 2
1
8
2
7
3
6
4
5
Line 3
Line 4
figure 1 - bidirectional common-mode protection
The SLVU2.8-8 provides 4 lines of protection in a common mode configuration. Circuit connectivity is as follows:
⢠Line 1 connected to Pin 1
⢠Line 2 connected to Pin 8
⢠Line 3 connected to Pin 5
⢠Line 4 connected to Pin 4
⢠Pins 2, 3, 6, 7 are connected to ground
SLVU2.8-8
1
Line Pair 1
2
3
Line Pair 2
4
8
Line Pair 3
7
6
Line Pair 4
5
figure 2 - bidirectional differential-mode protection
The SLVU2.8-8 provides four line pairs in a differential mode configuration. Circuit connectivity is as follows:
⢠Line Pair 1 connected to Pins 1 & 2
⢠Line Pair 2 connected to Pins 3 & 4
⢠Line Pair 3 connected to Pins 5 & 6
⢠Line Pair 4 connected to Pins 7 & 8
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
⢠The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
⢠The path length between the TVS device and the protected line should be minimized.
⢠All conductive loops including power and ground loops should be minimized.
⢠The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
⢠Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.
05181.R5 10/12
Page 5
www.protekdevices.com
|
▷ |