PSMS05_11 Datasheet, PDF (5/8 Pages) Protek Devices – MULTI-LINE TVS ARRAY
Only One Name Means ProTek’Tion™
application information
3
2
1
Line 1
Line 2
PSMS05 & PSMS05C
4
5
6
Line 3
Line 4
figure 1 - common-mode i/o port protection (unidirectional)
Circuit connectivity is as follows:
• Line 1 connected to pin 1.
• Line 2 connected to pin 3.
• Line 3 connected to pin 4.
• Line 4 connected to pin 6.
• Pin 5 connected to ground.
• Pin 6 not connected.
3
2
1
Line 1
Line 2
4
5
6
Line 3
Line 4
figure 1 - common-mode i/o port protection (bidirectional)
Circuit connectivity is as follows:
• Line 1 connected to pin 1.
• Line 2 connected to pin 3.
• Line 3 connected to pin 4.
• Line 4 connected to pin 5.
• Pin 6 connected to ground.
• Pin 2 not connected.
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
• The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
• The path length between the TVS device and the protected line should be minimized.
• All conductive loops including power and ground loops should be minimized.
• The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
• Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.