English
Language : 

PAM12SO824 Datasheet, PDF (5/8 Pages) Protek Devices – 600 WATT MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY
Only One Name Means ProTek’Tion™
application information
Line 1
Line 2
1
8
2
7
3
6
4
5
Line 3
Line 4
figure 1 - bidirectional common-mode protection
The PAM12SO824 provides 4 lines of protection in a common mode configuration. Circuit connectivity is as follows:
• Line 1 connected to Pin 1.
• Line 2 connected to Pin 7.
• Line 3 connected to Pin 3.
• Line 4 connected to Pin 5.
• Pins 2, 4, 7 and 7 are connected to ground.
• External diode to ground is a low capacitance diode of less than 10pF.
PAM12SO824
1
Line Pair 1
2
3
Line Pair 2
4
8
Line Pair 1
7
6
Line Pair 2
5
figure 2 - bidirectional differential-mode protection
The PAM12SO824 provides two line pairs in a differential mode configuration. Circuit connectivity is as follows:
• Line Pair 1 connected to Pins 1, 2, 7 and 8.
• Line Pair 2 connected to Pins 3, 4, 5 and 6.
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
• The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
• The path length between the TVS device and the protected line should be minimized.
• All conductive loops including power and ground loops should be minimized.
• The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
• Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.
05356.R0 12/11
Page 5
www.protekdevices.com