English
Language : 

PHP8.4_12 Datasheet, PDF (2/5 Pages) Protek Devices – AC POWER BUS VOLTAGE SUPPRESSOR
Only One Name Means ProTek’Tion™
typical device characteristics
PHP8.4 - PIP500
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER
SYMBOL
Peak Pulse Power (tp = 10/1000µs) - See Figure 1
PPP
Operating Temperature
TL
Storage Temperature
TSTG
Steady State Power Dissipation @ 50°C
TA
VALUE
7.5 & 15
-55 to 150
-55 to 150
7.5
UNITS
kilowatts
°C
°C
Watts
PART
NUMBER
ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified
AVERAGE
RMS
VOLTAGE
RATED
STAND-OFF
VOLTAGE
minimum
breakdown
voltage
(Note 1)
MAXIMUM
CLAMPING
VOLTAGE
(Fig. 2)
MAXIMUM
LEAKAGE
CURRENT
MAXIMUM
peak pulse
current
MAXIMUM
peak pulse
power
VRMS
VOLTS
VWM
VOLTS
@1mA
V(BR)
VOLTS
@ IPPM
VC
volts
@VWM
ID
µA
IPPM
amps
@ 1ms
PPP
kilowatts
PHP8.4
8.4
12.0
14
22
250
341
7.5
PIP8.4
8.4
12.0
14
22
250
341
7.5
PHP24
24.0
34.0
40
67
250
112
7.5
PIP24
24.0
34.0
40
67
250
112
7.5
PHP30
30.0
42.5
50
84
250
90
7.5
PIP30
30.0
42.5
50
84
250
90
7.5
PHP60
60.0
85.0
100
167
250
90
15
PIP60
60.0
85.0
100
167
250
90
15
PHP120*
120.0
170.0
200
319
250
47
15
PIP120*
120.0
170.0
200
319
250
47
15
PHP208
208.0
295.0
347
536
250
28
15
PIP208
208.0
295.0
347
536
250
28
15
PHP250*
250.0
354.0
418
652
250
23
15
PIP250*
250.0
354.0
418
652
250
23
15
PHP275
275.0
390.0
460
710
250
21
15
PHP440
440.0
623.0
735
1138
250
13.2
15
PIP440
440.0
623.0
735
1138
250
13.2
15
PHP500*
500.0
708.0
835
1292
250
11.6
15
PIP500*
500.0
708.0
835
1292
250
11.6
15
NOTE
1. A * indicates that this series is recommended for marine applications. For military and aerospace applications, use the PHP Series, for industrial applications, use the PIP Series.
2. The following voltages have a peak pulse power rating of 7,500 Watts for an 10/1000µs waveshape (see Figure 1): 8.4V, 24V and 30V.
05027.R9 9/12
Page 2
www.protekdevices.com