DLZ-5_07 Datasheet, PDF (1/4 Pages) Protek Devices – STANDARD CAPACITANCE TVS ARRAY | |||
|
DLZ-5
thru
DLZ-30CA
STANDARD CAPACITANCE TVS ARRAY
APPLICATIONS
â Military & Aerospace Data Line Protection
â RS-232 & RS-423 Data Lines
â Microprocessor Based Equipment
â Multiple Data & Power Bus Line Protection
IEC COMPATIBILITY (EN61000-4)
â 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
â 61000-4-4 (EFT): 40A - 5/50ns
â 61000-4-5 (Surge): 24A, 8/20µs Level 2 (Line-Ground) & Level 3 (Line-Line)
16 PIN CERAMIC
FEATURES
â MIL-STD-461 Compatible
â Protects I/O Devices
â Satisfies Military NEMP Requirements
â 1300 Watts Peak Pulse Power per Line (tp=8/20µs)
â Unidirectional & Bidirectional Configurations
â ESD Protection > 40 kilovolts
â Internal Common Ground
â Available in Multiple Voltage Types: 5.0V to 30.0V
â Multiple TVS Array: Protects up to 15 Lines
MECHANICAL CHARACTERISTICS
â Ceramic 16 Pin Hermetically Sealed Package
â Weight 3.2 grams (Approximate)
â Flammability Rating UL 94V-0
â Marking: Logo, Part Number, Date Code & Pin One Defined By Flag on Lead
â Screening Available Upon Request - The DLZ series can be screened upon request for
military requirements in accordance with MIL-PRF-19500 (applicable test). Standard
screening is available based on the following options:
H1 - 100% screening per test plans 05227 & 05229
H2 - 100% screening per test plans 05228 & 05230
â Screening to DESC Drawing #94029 (Bidirectional) & #94030 (Unidirectional) is also
available
PIN CONFIGURATIONS
UNIDIRECTIONAL
16
15
14
13
12
11
10
9
BIDIRECTIONAL
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
05008.R7 2/07
1
www.protekdevices.com
|
▷ |