English
Language : 

PSD27 Datasheet, PDF (1/1 Pages) Powersem GmbH – Three Phase Rectifier Bridge
SLIM-PACTM
Three Phase
Rectifier Bridge
PSD 27
IdAV
VRRM
= 28 A
= 600-1200V
Preliminary Data Sheet
VRSM
VDSM
VRRM
VDRM
Type
+
(V) (V)
~H
700 600 PSD 27/06
~A
900 800 PSD 27/08
~N
1300 1200 PSD 27/12
K-
Features
Symbol
I*dAV
IFSM
∫ i2 dt
TVJ
TVJM
Tstg
VISOL
Md
Weight
Test Conditions
Maximum Ratings
TC = 100 °C, (per module)
28
TVJ = 45 °C t = 10 ms (50 Hz), sine
100
VR = 0
t = 8.3 ms (60 Hz), sine
106
TVJ = TVJM
t = 10 ms (50 Hz), sine
85
VR = 0
t = 8.3 ms (60 Hz), sine
90
TVJ = 45 °C t = 10 ms (50 Hz), sine
50
VR = 0
TVJ = TVJM
VR = 0
t = 8.3 ms (60 Hz), sine
47
t = 10 ms (50 Hz), sine
36
t = 8.3 ms (60 Hz), sine
33
-40... + 150
150
-40... + 125
50/60 Hz, RMS t = 1 min
2500
IISOL ≤ 1 mA
t=1s
Mounting torque
typ.
(M4)
3000
1.5 - 1.8
14 - 16
10
A
A
A
A
A
A²s
A²s
A²s
A²s
°C
°C
°C
V∼
V∼
Nm
lb.in.
g
Symbol
IR
VF
VTO
rT
RthJC
RthJH
ds
dA
a
Test Conditions
Characteristic Value
VR = VRRM, TVJ = TVJM
≤
VR = VRRM, TVJ = 25°C
≤
IF = 7 A,
TVJ = 25 °C
≤
For power-loss calculations only
0.3
mA
5
mA
1.12
V
0.8
V
40
mΩ
per diode; DC
2.3 K/W
per module
per diode; DC
0.39 K/W
2.8
K/W
per module
0.47
K/W
Creeping distance on surface
Creeping distance in air
Max. allowable acceleration
8.2
mm
9.7
mm
50
m/s²
•
Package with DCB ceramic base plate
•
Isolation voltage 3000 V∼
•
Planar glass passivated chips
•
Low forward voltage drop
•
Leads suitable for PC board
soldering
•
UL registered, E 148688
Applications
•
Supplies for DC power equipment
•
Input rectifier for PWM inverter
•
Battery DC power supplies
•
Field supply for DC motors
Advantages
•
Easy to mount with two screws
•
Space and weight savings
•
Improved temperature and power
cycling capability
•
High power density
•
Small and light weight
Package style and outline
Dimensions in mm (1mm = 0.0394“)
R0,75
Data according to IEC 60747 refer to a single diode unless otherwise stated
*- for resistive load at bridge output
39
47+ 0,2
-0,2
POWERSEM GmbH, Walpersdorfer Str. 53
D - 91126 Schwabach
Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20
 2005 POWERSEM reserves the right to change limits, test conditions and dimensions