LNK574
Parameter
Conditions
Symbol
SOURCE = 0 V; TJ = -40 to 125 °C
Min
Typ
Max Units
(Unless Otherwise Specified)
Output
ON-State
Resistance
Breakdown
Voltage
RDS(ON)
ID = 13 mA
TJ = 25 °C
TJ = 100 °C
48
55
W
76
88
BVDSS
VBP = 6.2 V, TJ = 25 °C
700
V
DRAIN Supply
Voltage
50
V
Auto-Restart
ON-Time
Auto-Restart
OFF-Time
tAR
VIN = 85 VAC, TJ = 25 °C,
See Note D
145
ms
1.0
s
Output Enable Delay
tEN
See Figure 8
14
ms
NOTES:
A. IDSS is the worse case off state leakage specification at 80% of BVDSS and maximum operating junction temperature.
B. This parameter is derived from characterization.
C. Output frequency specification applies to low line input voltage in the final application. The controller is designed to reduce output
frequency by approximately 20% at high line input voltages to balance low line and high line maximum output power.
D. The auto-restart on-time/off-time is increased by 20% at high line input 265 VAC.
E. LinkZero-LP shuts down if current into BYPASS pin reaches ISD at BPSHUNT voltage.
www.powerint.com
9