EPR-000013 Datasheet, PDF (50/56 Pages) Power Integrations, Inc. – Engineering Prototype Report (EP13) 43 W / 57 W pk, 5 Output TOPSwitch팜-GX (TOP246Y) Power Supply
EPR-000013 – 43 W Multiple Output TOP246 Power Supply
08-May-2001
IRIPPLE1
PIVS1
CMS1
AWGS1
DIAS1
ODS1
2nd output
VO2
IO2
PO2
VD2
NS2
ISRMS2
IRIPPLE2
PIVS2
CMS2
AWGS2
DIAS2
ODS2
3rd output
VO3
IO3
PO3
VD3
NS3
ISRMS3
IRIPPLE3
PIVS3
CMS3
AWGS3
DIAS3
ODS3
12.0
0.600
1.4
30.0
0.030
1.4
4.35 Amps
16 Volts
1079 Cmils
19 AWG
0.91 mm
5.13 mm
Volts
Amps
7.20 Watts
Volts
7.05
1.012 Amps
0.81 Amps
37 Volts
202 Cmils
27 AWG
0.36 mm
2.18 mm
Volts
Amps
0.90 Watts
Volts
16.53
0.051 Amps
0.04 Amps
89 Volts
10 Cmils
39 AWG
0.09 mm
0.93 mm
Output Capacitor RMS Ripple Current
Output Rectifier Maximum Peak Inverse Voltage
Output Winding Bare Conductor minimum circular
mils
Wire Gauge (Rounded up to next larger standard
AWG value)
Minimum Bare Conductor Diameter
Maximum Outside Diameter for Triple Insulated Wire
Output Voltage
Output DC Current
Output Power
Output Diode Forward Voltage Drop
Output Winding Number of Turns
Output Winding RMS Current
Output Capacitor RMS Ripple Current
Output Rectifier Maximum Peak Inverse Voltage
Output Winding Bare Conductor minimum circular
mils
Wire Gauge (Rounded up to next larger standard
AWG value)
Minimum Bare Conductor Diameter
Maximum Outside Diameter for Triple Insulated Wire
Output Voltage
Output DC Current
Output Power
Output Diode Forward Voltage Drop
Output Winding Number of Turns
Output Winding RMS Current
Output Capacitor RMS Ripple Current
Output Rectifier Maximum Peak Inverse Voltage
Output Winding Bare Conductor minimum circular
mils
Wire Gauge (Rounded up to next larger standard
AWG value)
Minimum Bare Conductor Diameter
Maximum Outside Diameter for Triple Insulated Wire
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 50 of 56