English
Language : 

EPR-32 Datasheet, PDF (4/36 Pages) Power Integrations, Inc. – Engineering Prototype Report for EP-32 − TOPSwitch-GX 25 W Multiple Output DVD, Set-top Box Power Supply Using TOP245P
EPR-32 - 25 W Multiple Output TOP245P Supply
13-Jul-06
2 Power Supply Specification
Description
Input
Voltage
Frequency
No-load Input Power
Output
Output Voltage 1
Output Ripple Voltage 1
Output Current 1
Output Voltage 2
Output Ripple Voltage 2
Output Current 2
Output Voltage 3
Output Ripple Voltage 3
Output Current 3
Output Voltage 4
Output Ripple Voltage 4
Output Current 4
Total Output Power
Continuous
Peak
Efficiency
Environmental
Conducted EMI
Safety
Surge
Ambient Temperature
Symbol Min
Typ
Max Units
Comment
VIN
fLINE
85 100/115/230 265
47
50/60
64
0.1
VAC
Hz
W
2 Wire
(No Protective Earth Ground)
Measured at 265 VAC
VOUT1
VRIPPLE1
IOUT1
VOUT2
VRIPPLE2
IOUT2
VOUT3
VRIPPLE3
IOUT3
VOUT4
VRIPPLE4
IOUT4
3.20
0.30
4.75
0.30
11.16
100
-21.62
30
POUT
4.4
POUT_PEAK
η
3.30
0.60
5.00
1.20
12.00
200
-24.00
50
20
75
3.45
50
2.0
5.25
75
2.5
12.84
100
500
-26.9
100
50
25
V
±5%
mV
20 MHz Bandwidth
A
V
±5%
mV
20 MHz Bandwidth
A
V
±7%
mV
20 MHz Bandwidth
mA
V
-10% / +12%
mV
20 MHz Bandwidth
mA
W
W
%
Measured at POUT (26 W), 25 oC
Meets CISPR22B / EN55022B
Designed to meet
IEC950/UL1950 Class II
2
3
kV
TAMB
0
50
oC
Table 1 – Power Supply Specification.
1.2 / 50 µs surge, IEC 1000-4-
5, Series Impedance:
Differential Mode: 2 Ω
Common Mode: 12 Ω
Free convection, sea level
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 4 of 36