English
Language : 

TOP242-250 Datasheet, PDF (35/52 Pages) Power Integrations, Inc. – TOPSwitch-GX Family Extended Power, Design Flexible, EcoSmart, Integrated Off-line Switcher
TOP242-250
Parameter
Conditions
Symbol
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 53
Min
Typ
Max Units
(Unless Otherwise Specified)
SHUTDOWN/AUTO-RESTART (cont.)
Auto-Restart Duty
Cycle
DC(AR)
4
8
%
Auto-Restart
Frequency
f(AR)
1.0
Hz
MULTI-FUNCTION (M), LINE-SENSE (L) AND EXTERNAL CURRENT LIMIT (X) INPUTS
Line Under-
Voltage Threshold
Current and Hys-
IUV
teresis (M or L Pin)
TJ = 25 °C
Threshold
Hysteresis
44
50
54
µA
30
µA
Line Overvoltage
or Remote ON/OFF
Threshold Current
IOV
and Hysteresis
(M or L Pin)
TJ = 25 °C
Threshold
Hysteresis
210
225
240
µA
8
µA
L Pin Voltage
Threshold
VL(TH)
0.5
1.0
1.6
V
Remote ON/OFF
Negative
Threshold Current
and Hysteresis
(M or X Pin)
IREM (N)
TJ = 25 °C
Threshold
Hysteresis
-35
-27
-20
µA
5
µA
L or M Pin Short
Circuit Current
IL(SC) or
IM(SC)
VL, VM = VC
300
400
520
µA
X or M Pin Short
Circuit Current
IX(SC) or
IM(SC)
VX, VM = 0 V
Normal Mode
Auto-Restart Mode
-300
-110
-240
-90
-180
-70
µA
L or M Pin Voltage
(Positive Current)
X Pin Voltage
(Negative Current)
M Pin Voltage
(Negative Current)
VL, VM
VX
VM
IL or IM = 50 µA
1.90
2.50
3.00
V
IL or IM = 225 µA
2.30
2.90
3.30
IX = -50 µA
1.26
1.33
1.40
V
IX = -150 µA
1.18
1.24
1.30
IM = -50 µA
1.24
1.31
1.39
V
IM = -150 µA
1.13
1.19
1.25
Maximum Duty
Cycle Reduction
Onset Threshold
Current
IL(DC) or
IM(DC)
TJ = 25 °C
40
60
75
µA
35 M
12/04