13 Conducted EMI
Conducted emissions tests were performed at 115 VAC and 230 VAC at full load (12 V,
1 A). Measurements were taken with an Artificial Hand connected and a floating DC
output load resistor. A DC output cable was included.
Composite EN55022B / CISPR22B conducted limits are shown. In all cases there was
excellent (>10 dB) margin.
13.1 115 VAC, Full Load
Line
Neutral
Artificial Hand Connected to Output Return
Artificial Hand Connected to Output Return
Output Floating
Output Floating
Figure 27 – Conducted EMI at 115 VAC.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com