9 Test Results
Thermal and Dissipation Data
TOP247 dissipation at 90 VAC and 5 V at 15 A, 3.3 V at 7 A, 12 V at 4 A (approximately
140 W) was measured 5.4 W.
The unit was enclosed in a standard ATX enclosure. The ambient external temperature
around the enclosure was 25 °C and the internal ambient in the enclosure in the box
near TOP247 heatsink was measured 37 °C.
The TOP247 source tab temperature for above conditions was measured 53 °C.