English
Language : 

CD421690B Datasheet, PDF (3/4 Pages) Power Integrations, Inc. – POW-R-BLOK Dual SCR/Diode Isolated Module 90 Amperes / Up to 1800 Volts
Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (724) 925-7272
CD42__90B
CD47__90B
POW-R-BLOKTM
Dual SCR/Diode Isolated Module
90 Amperes / Up to 1800 Volts
Electrical Characteristics, TJ=25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Max. Units
Repetitive Peak Forward Leakage Current
Repetitive Peak Reverse Leakage Current
Peak On-State Voltage
Threshold Voltage, Low-level
Slope Resistance, Low-level
Minimum dV/dt
Turn-Off Time (Typical)
Gate Trigger Current
Gate Trigger Voltage
Non-Triggering Gate Voltage
Non-Triggering Gate Current
Holding Current
Latching Current
IDRM
IRRM
V TM / VFM
V(TO)1
rT1
dV/dt
t off
IGT
VGT
VGDM
IGDM
IH
IL
Up to 1800V, TJ=125°C
Up to 1800V, TJ=125°C
ITM / IFM =300A
TJ = 125°C, I = 16.7% x πIT(AV) to πIT(AV)
Tj=125°C, Up to 800V
Tj=125°C, 1200 - 1800V
TJ = 25°C
Tj= 25°C, VD=6V, Resistive Load
Tj= 25°C, VD=6V, Resistive Load
Tj=125°C, VD=VDRM
Tj=125°C, VD=VDRM
TJ = 25°C
TJ = 25°C
20
20
1.65
0.9
2.0
500
1000
40 - 100 (Typical)
150
3.0
0.25
6
250
600
mA
mA
V
V
mΩ
V/µs
V/µs
µs
mA
Volts
Volts
mA
mA
mA
Thermal Characteristics
Characteristics
Thermal Resistance, Junction to Case
DC Operation
Thermal Resistance, Case to Sink Lubricated
Symbol
RΘJ-C
RΘC-S
Per Module, both conducting
Per Junction, both conducting
Per Module
Max.
0.14
0.28
0.1
Units
°C/W
°C/W
°C/W
Revision Date: 04/28/2009