EPR-33 – 45 W External Adapter Supply
11.5 Output Ripple Measurements
11.5.1 Ripple Measurement Technique
For DC output ripple measurements, a modified oscilloscope test probe must be utilized
in order to reduce spurious signals due to pickup. Details of the probe modification are
provided in Figure 24 and Figure 25.
The 5125BA probe adapter is affixed with two capacitors tied in parallel across the probe
tip. The capacitors include one (1) 0.1 µF/50 V ceramic type and one (1) 1.0 µF/50 V
aluminum electrolytic. The aluminum electrolytic type capacitor is polarized, so
proper polarity across DC outputs must be maintained (see below).
Probe Ground
Probe Tip
Figure 24 - Oscilloscope Probe Prepared for Ripple Measurement
(End Cap and Ground Lead Removed).
Figure 25 - Oscilloscope Probe with Probe Master 5125BA BNC Adapter
(Modified with wires for probe ground for ripple measurement
and two parallel decoupling capacitors added).
Page 23 of 32