English
Language : 

TOP260YN Datasheet, PDF (20/51 Pages) Power Integrations, Inc. – Enhanced EcoSmart™, Integrated Off-Line Switcher with Advanced Feature Set and Extended Power Range
TOP252-262
Typical Uses of MULTI-FUNCTION (M) Pin (cont.)
+
QR can be an optocoupler
output or can be replaced
by a manual switch.
DC
Input
Voltage
QR
ON/OFF
47
-
kΩ
D
M
CONTROL
C
S
Figure 37. Active-on (Fail Safe) Remote ON/OFF.
PI-2519-040501
+
QR can be an optocoupler
output or can be replaced
by a manual switch.
DC
Input
Voltage
RIL
ON/OFF
QR
1-6 kΩ
D
M
CONTROL
C
S
For RIL = 12 kΩ
ILIMIT = 61%
For RIL = 19 kΩ
ILIMIT = 37%
PI-4735-092107
Figure 38. Active-on Remote ON/OFF with Externally Set Current Limit
(see M Pin Operation Description).
+
QR can be an optocoupler
output or can be replaced
by a manual switch.
ON/OFF
DC
Input
Voltage
7 kΩ
D
QR
RMC
M
RIL 12 kΩ
CONTROL
C
24 kΩ
RMC = 2RIL
-
S
PI-4736-060607
Figure 39. Active-off Remote ON/OFF with Externally Set Current Limit
(see M Pin Operation Description).
+
DC
Input
Voltage
Reset 10 kΩ
VUV = IUV × RLS + VM (IM = IUV)
VOV = IOV × RLS + VM (IM = IOV)
For RLS = 4 MΩ
RLS
4 MΩ VUV = 102.8 VDC
VOV = 451 VDC
Sense Output Voltage
D
QR
DCMAX @ 100 VDC = 76%
M
DCMAX @ 375 VDC = 41%
CONTROL
C
-
S
PI-4757-120307
Figure 40. Line-Sensing for Undervoltage, Overvoltage, Line Feed-Forward and
Latched Output Overvoltage Protection with Device Reset.
20
Rev. H 06/13
www.powerint.com