English
Language : 

TOP270KG-TL Datasheet, PDF (14/40 Pages) Power Integrations, Inc. – Integrated Off-Line Switcher with EcoSmart Technology for Highly Efficient Power Supplies
TOP264-271
Typical Uses of VOLTAGE MONITOR (V) and EXTERNAL CURRENT LIMIT (X) Pins (cont.)
+
ILIMIT = 100% @ 100 VDC
+
ILIMIT = 53% @ 300 VDC
RLS 2.5 MΩ
QR can be an optocoupler
output or can be replaced by
a manual switch.
DC
Input
Voltage
-
D
CONTROL
C
S
X
RIL
6 kΩ
Figure 19. Current Limit Reduction with Line Voltage.
PI-5465-061009
DC
Input
Voltage
D
CONTROL
C
S
X
-
QR
ON/OFF
47 KΩ
PI-5466-061009
Figure 20. Active-On (Fail Safe) Remote-ON/OFF, and Latch Reset.
+
DC
Input
Voltage
QR can be an optocoupler
output or can be replaced
by a manual switch.
D
CONTROL
C
For RIL = 12 kΩ
ILIMIT = 61%
For RIL = 19 kΩ
ILIMIT = 37%
S
X
-
RIL QR
ON/OFF
16 kΩ
PI-5531-072309
Figure 21. Active-On Remote-ON/OFF with Externally Set Current Limit,
and Latch Reset
+
DC
Input
Voltage
-
VUV = IUV × RLS + VV (IV = IUV)
VOV = IOV × RLS + VV (IV = IoV)
RLS
4 MΩ
DCMAX@100 VDC = 76%
DCMAX@375 VDC = 41%
QR can be an optocoupler
D
V
output or can be replaced
by a manual switch.
CONTROL
C
For RIL = 12 kΩ
ILIMIT = 61%
S
X
RIL QR
ON/OFF
16 kΩ
PI-5467-061009
Figure 22. Active-On Remote-ON/OFF with Line-Sense and External
Current Limit, and Latch Reset.
+
DC
Input
Voltage
-
VUV = IUV x RLS + VV (IV = IUV)
VOV = IOV x RLS + VV (IV = IoV)
RLS
4 MΩ For RLS = 4 MΩ
VUV = 102.8 VDC
VOV = 451 VDC
D
V
DCMAX @ 100 VDC = 76%
DCMAX @ 375 VDC = 41%
CONTROL
C
S
X
For RIL = 12 kΩ
ILIMIT = 61%
RIL
12 kΩ
See Figure 37 for
other resistor values
(RIL) to select different
ILIMIT values.
Figure 23. Line Sensing and Externally Set Current Limit.
+
DC
Input
Voltage
-
Typ. 65 VAC brownout threshold.
<3 s AC latch reset time.
Higher gain QR allows increasing R1/
decreasing C1 for lower no-load input
power.
D
CONTROL
C
S
X
RIL QR
R1
4 MΩ 1N4007
R2
39 kΩ
AC
C1 Input
47 nF
PI-5652-110609
Figure 24. Externally Set Current Limit, Fast AC Latch Reset and Brown-Out.
14
Rev. E 08/12
www.powerint.com