8.3 Materials
Item
Description
[1] Core: PC40EE16-Z, TDK or equivalent Gapped for AL of 139 nH/T2
[2] Bobbin: Horizontal 10 pin
[3] Magnet Wire: #36 AWG
[4] Magnet Wire: #35 AWG
[5] Magnet Wire: #31 AWG
[6] Triple Insulated Wire: #28 AWG.
[7] Tape: 3M 1298 Polyester Film, 2.0 mils thick, 8.4 mm wide
[8] Varnish
8.4 Transformer Build Diagram
WD#5 Secondary
3
2
1
5
10
8
WD#4 Shield
WD#3 Bias
WD#2 Primary
4
5
WD#1
Cancellation
Figure 5 – Transformer Build Diagram
Page 10 of 23
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com