English
Language : 

PS21542-G Datasheet, PDF (4/6 Pages) Powerex Power Semiconductors – Intellimod™ Module Dual-In-Line Intelligent Power Module (5 Amperes/600 Volts)
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21542-G
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Control Sector
Supply Voltage
VD
Applied between VP1-VNC, VN1-VNC
13.5 15.0 16.5 Volts
VDB
Applied between VUFB-VUFS,
13.5 15.0 16.5 Volts
VVFB-VVFS, VWFB-VWFS
Circuit Current
ID
VD = 15V, VCIN = 5V, VDB = 15V,
—
4.25 8.50
mA
Total of VP1-VNC, VN1-VNC
VD = 15V, VCIN = 0V, VDB = 15V,
—
4.95 9.70
mA
Total of VP1-VNC, VN1-VNC
VD = 15V, VCIN = 5V, VDB = 15V,
—
0.50 1.00
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
VD = 15V, VCIN = 0V, VDB = 15V,
—
0.50 1.00
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
Fault Output Voltage
VFOH
VSC = 0V, FO Circuit: 10k Ω to 5V Pull-up
4.9
—
—
Volts
VFOL
VSC = 1V, FO Circuit: 10k Ω to 5V Pull-up
—
0.8
1.2
Volts
VFO(sat)
VSC = 1V, IFO = 15mA
0.8
1.2
1.8
Volts
PWM Input Frequency
fPWM
Tj ≤ 125°C, Tf ≤ 100°C
—
5
—
kHz
Allowable Dead Time
tDEAD
Relates to Corresponding Input Signal for
3
—
—
µS
Blocking Arm Shoot-through (Tf ≤ 100°C)
Short Circuit Trip Level*
VSC(ref)
Tj = 25°C, VD = 15V*
0.45
0.5
0.55 Volts
Supply Circuit Under-voltage
UVDBt
Trip Level, Tj ≤ 125°C
10.0
—
12.0 Volts
UVDBr
Reset Level, Tj ≤ 125°C
10.5
—
12.5 Volts
UVDt
Trip Level, Tj ≤ 125°C
10.3
—
12.5 Volts
UVDr
Reset Level, Tj ≤ 125°C
10.8
—
13.0 Volts
Fault Output Pulse Width**
tFO
CFO = 22nF
1.0
1.8
—
mS
ON Threshold Voltage (H-side)
Vth(on)
Applied between UP, VP, WP-VNC
0.8
1.4
2.0
Volts
OFF Threshold Voltage (H-side)
Vth(off)
2.5
3.0
4.0
Volts
ON Threshold Voltage (L-side)
Vth(on)
Applied between UN, VN, WN-VNC
0.8
1.4
2.0
Volts
OFF Threshold Voltage (L-side)
Vth(off)
2.5
3.0
4.0
Volts
* Short Circuit protection operates only at the low-arms. Please select the value of the external shunt resistor such that the SC trip level is less than 8.5A.
**Fault
CFO
signal is asserted when the low-arm short circuit or control supply under-voltage
according to the following approximate equation: CFO = (12.2 x 10-6) x tFO {F} .
protective
functions
operate.
The
fault
output
pulse-width
tFO
depends
on
the
capacitance
value
of
136