English
Language : 

CM600YE2P-12F Datasheet, PDF (3/5 Pages) –
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
CM600YE2N-12F / CM600YE2P-12F
TLI-Series (Three Level Inverter) IGBT
600 Amperes/600 Volts
Electrical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max. Units
Inverter Part
Collector-Cutoff Current
Gate-Emitter Threshold Voltage
Gate Leakage Current
Collector-Emitter Saturation Voltage
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge
Turn-on Delay Time
Turn-on Rise Time
Turn-off Delay Time
Turn-off Fall Time
Reverse Recovery Time
Reverse Recovery Charge
Emitter-Collector Voltage
External Gate Resistance
Clamp Diode Part
Repetitive Reverse Current
Forward Voltage Drop
Reverse Recovery Time
Reverse Recovery Charge
ICES
VGE(th)
IGES
VCE(sat)
Cies
Coes
Cres
QG
td(on)
tr
td(off)
tf
trr*1
Qrr*1
VEC*1
RG
VCE = VCES, VGE = 0V
IC = 60mA, VCE = 10V
VGE = VGES, VCE = 0V
IC = 600A, VGE = 15V, Tj = 25°C
IC = 600A, VGE = 15V, Tj = 125°C
VCE = 10V, VGE = 0V
VCC = 300V, IC = 600A, VGE = 15V
VCC = 300V, IC = 600A,
VGE1 = VGE2 = 15V,
RG = 3.3Ω,
Inductive Load Switching Operation,
IE = 600A
IE = 600A, VGE = 0V
–
–
1
5
6
7
–
–
80
–
1.6
2.2
–
1.6
–
–
–
160
–
–
11
–
–
6.0
–
3720
–
–
–
700
–
–
600
–
–
1100
–
–
300
–
–
200
–
2.25
–
–
–
3.1
3.3
–
10
mA
Volts
μA
Volts
Volts
nF
nF
nF
nC
ns
ns
ns
ns
ns
ns
μC
Ω
IRRM
VFM
trr
Qrr
VR = VRRM
–
IF = 600A
–
IF = 600A, VCC = 300V,
–
VGE1 = VGE2 = 15V, RG = 3.3Ω,
–
Inductive Load Switching Operation
–
1
–
2.8
–
300
7.68
–
mA
Volts
ns
μC
Thermal and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Thermal Resistance, Junction to Case*4
Rth(j-c')Q
Inverter IGBT
–
Thermal Resistance, Junction to Case*4
Rth(j-c')D
Inverter FWDi
–
Thermal Resistance, Junction to Case*4
Rth(c-f)D
Clamp Diode Part
–
Contact Thermal Resistance*5
Rth(c-f) Thermal Grease Applied (per 1 Module) –
*4 TC measured point is just under the chips. If using this value, Rth(f-a) should be measured just under the chips.
*5 Typical value is measured by using thermally conductive grease of λ = 0.9 [W/(m • K)].
Typ.
–
–
–
0.028
Max.
0.067
0.13
0.09
–
Units
°C/W
°C/W
°C/W
°C/W
01/10 Rev. 1
3