English
Language : 

FNP300-1012 Datasheet, PDF (2/6 Pages) Power-One – AC-DC Power Supply 12V, 24V, 48V Output, 300 Watts
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-
term reliability, and cause permanent damage to the converter.
Parameter
Input Voltage
Operating Temperature
Storage Temperature
Conditions/Description
Continuous
Transient, 60 ms
Ambient
Vi min-Vi max, Io nom, cooling by internal fan
Non-operational
Min
Max
Units
264
VAC
300
VAC
0
55
°C
-40
85
°C
Environmental, Mechanical, & Reliability Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Operating Humidity
Storage Humidity
Shock
Sinusoidal Vibration
MTBF
Conditions/Description
Relative humidity, non-condensing
Relative humidity, non-condensing
IEC/EN 60068-2-27, 11 ms
IEC/EN 60068-2-6
2-8 Hz
8-200 Hz
200-500 Hz
MIL-HDBK-217F Notice 2, GB, 25 °C
Min Nom Max Units
10
90
%
5
95
%
30
gn
7.5
mil
2
gn
4
gn
200
kh
Isolation Specifications
The electric strength test is performed in the factory as routine test in accordance with EN 550116, IEC/EN 60950,
and UL 1950 and should not be repeated in the field. Power-One will not honor any warranty claims resulting from
electric strength field tests.
Parameter
Insulation Safety Rating
Electric Strength Test Voltage
Conditions/Description
Input/Case
Input/Output
Output/Case
Input/Case
Input/Output
Output/Case
Min Nom Max
Basic
Reinforced
Functional
2.121
4.2
0.5
Units
kVDC
kVDC
kVDC
EMC Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Electrostatic Discharge
Electromagnetic Field
Eletr. Fast Transients / Burst
Surge
Voltage Dips and Interruptions
RF Conducted Immunity
Description
IEC/EN 61000-4-2, level 4 (contact/air)
IEC/EN 61000-4-3, level 3
IEC/EN 61000-4-4, level 4 (direct/capacitive)
IEC/EN 61000-4-5, level 3 (L/L, L/C)
IEC/EN 61000-4-11
IEC/EN 61000-4-6
Emissions Radiated/Conducted
Harmonics
Voltage Fluctuation and Flicker
CISPR 22/EN 55022/EN 61204
IEC/EN 61000-3-2
IEC/EN 61000-3-3
Criterion
8/15 kV, criterion B
10 V/m, criterion A
2/1 kV, criterion B
1/2 kV, criterion B
Criterion B
10 VAC, AM 80%, 1 kHz,
criterion A
Class B
Class B
Pass
BCD20015-G Rev. AB, 29-Mar-10
Page 2 of 6