English
Language : 

CC24500N Datasheet, PDF (2/2 Pages) Powerex Power Semiconductors – Super Fast Recovery Dual Diode Modules 50 Amperes/300-600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CC24_ _500N, CN24_ _500N
Super Fast Recovery Dual Diode Modules
50 Amperes/300-600 Volts
Absolute Maximum Ratings
Characteristics
Peak Reverse Blocking Voltage
Transient Peak Reverse Blocking Voltage (Non-Repetitive), t < 5ms
DC Reverse Blocking Voltage
DC Current, TC = 90°C
Peak One-Cycle Surge (Non-Repetitive) On-State Current (60Hz)
Peak One-Cycle Surge (Non-Repetitive) On-State Current (50Hz)
I2t (for Fusing), 8.3 milliseconds
Storage Temperature
Operating Temperature
Maximum Mounting Torque M4 Mounting Screw
Maximum Mounting Torque M5 Terminal Screw
Module Weight (Typical)
V Isolation
Symbol
VRRM
VRSM
VR(DC)
IF(DC)
IFSM
IFSM
I2t
TSTG
Tj
—
—
—
VRMS
CC2403500N
CN2403500N
300
360
240
50
1000
910
4200
-40 to 125
-40 to 150
12
17
90
2500
CC2406500N
CN2406500N
600
720
480
50
1000
910
4200
-40 to 125
-40 to 150
12
17
90
2500
Units
Volts
Volts
Volts
Amperes
Amperes
Amperes
A2sec
°C
°C
in.-lb.
in.-lb.
Grams
Volts
Electrical and Thermal Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
CC24_ _500N/CN24_ _500N
Blocking State Maximums
Reverse Leakage Current, Peak
Conducting State Maximums
Peak On-State Voltage
Switching Maximums
Reverse Recovery Time
Thermal Maximums
Thermal Resistance, Junction-to-Case
Thermal Resistance, Case-to-Sink (Lubricated)
IRRM
Tj = 125°C, VRRM = Rated
VFM
IFM = 50A
trr
IFM = 50A
di/dt = -100 A/␮s, VR = 1/2 VRRM
R␪(J-C)
R␪(C-S)
Per Module
Per Module
20
2.5
200
0.6
0.3
Units
mA
Volts
ns
°C/Watt
°C/Watt
D-44
MAXIMUM
ON-STATE CHARACTERISTICS
3.8
Tj = 25oC
3.4
3.0
2.6
2.2
1.8
1.4
1.0
0.6
100
101
102
103
INSTANTANEOUS ON-STATE CURRENT, IFM,
(AMPERES)
MAXIMUM
ALLOWABLE CASE TEMPERATURE
150
140
OPERATION
DC
130
SINGLE-PHASE
120
THREE-PHASE
110
100
90
80
70
60 RESISTIVE
50
INDUCTIVE
LOAD
40
0 10 20 30 40 50 60 70 80
AVERAGE ON-STATE CURRENT, IF(AV),
(AMPERES)
MAXIMUM
ON-STATE POWER DISSIPATION
90
OPERATION
80
DC
SINGLE-PHASE
70
THREE-PHASE
60
50
40
30
20
10
0
0
RESISTIVE
INDUCTIVE
LOAD
4 8 12 16 20 24 28 32
AVERAGE ON-STATE CURRENT, IF(AV),
(AMPERES)