English
Language : 

PE3P Datasheet, PDF (4/4 Pages) PowerDynamics, Inc – 3 PHASE, 3 WIRE, CHASSIS MOUNT EMI/RFI LINE FILTER.
PE3P Series
SCHEMATIC 5; CASE C6
TECHNICAL DATA
• Rated Voltage: 500VAC
• Rated Current: 10A, 20A, 30A, 40A, 50A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
L1
Line to Ground:
@ 500VAC, 60Hz: 2.0mA
L2
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
L3
• Temperature Range: -25C to +50C
E
R C1
R C1
R C1
L1
L1
L1
Cy Cy Cy
L'1
L2 C 2
C2
L'2
L2 C 2
L'3
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
PDI
Current
R
Cx1 Cx2 Cy
L1
L2
Comm. Mode (L-G) in MHz
P/N
Rating (A) (Ohms) (uF) (pF) (pF) (uH x 2) (uH x 2) .15 .5 1 5 10 30
PE3P10PS-5-C6
PE3P20PS-5-C6
PE3P30PS-5-C6
PE3P40PS-5-C6
PE3P50PS-5-C6
10
5.0
20
2.0
30
430K 3.3 2.2 3300 1.0
40
0.5
50
0.5
10.0
3.5
2.5
1.1
0.9
36 42 53 58 62 32
32 38 43 51 54 31
38 43 46 52 51 28
35 46 49 53 47 25
29 37 42 51 52 23
Diff. Mode (L-L) in MHz
.15 0.5 1 5 10 30
56 63 65
59 65 68
48 57 53
45 56 51
37 42 53
53 45 31
54 39 28
56 42 34
53 47 25
51 42 27
Dimensional Table
DIMENSIONS
CASE A B C D E F G (H) I J
K
L
G2 143 122112 84 100 77 54 34 23 23 2x 6x10 2x 5
G3 201180 170126184140 65 35 46 46 2x 10x14 2x 10
G4 237212200159 240180 80 50 70 70 2x 10x16 2x 12
M N OP
2.8 90.6 4.4 5.0
5 166 6.410.0
2.8210 8.715.0
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
52
e-mail: filtersales@powerdynamics.com • www.powerdynamics.com