English
Language : 

PBH Datasheet, PDF (2/2 Pages) Tyco Electronics – Miniature Power PCB Relay
PBH Series Example & Ordering Code
PBH 20 Q - 60 - 1 C U
CURRENT RATING (A):
= 16
= 20
TERMINAL:
6.3/0.25
4.0/0.187
3.0 -3.6L
8.0
2.0 -3.0L
6.6
UL 1015, 18AWG
STRANDED, 4”
QUICK CONNECT = Q
SOLDER
=S
WIRE
=W
OPTIONS:
NO BLEEDER RESISTOR & NO GROUND CHOKE
BLEEDER RESISTOR (1W, 1M)
BLEEDER RESISTOR (1W, 1M) & GROUND CHOKE
GROUND CHOKE (100µH)
= 00
= 60
= 80
= 90
COMPONENT LOCATIONS:
STANDARD TYPE
WITHOUT C(X); C(Y) ONLY
C(X) & C(Y) BEHIND L
WITHOUT C(Y); C(X) ONLY
WITHOUT C(Y); C(X) BEHIND L
=1
= 2
= 3
= 1M
= 2M
ATTENUATION CODE TABLE:
Non-Medical applications, select Attenuation code with corresponding component values from the table.
Case Code
F,O,U
F,O,U
F,O,U
Cap. Cx (µF)
0.1
0.1
0.33
Cap. Cy (pF)
2200
3300
2200
20A (mH)
0.5
=A
0.5
=B
0.5
=C
Medical applications, select Attenuation code with corresponding component values from the table.
Case Code
F,O,U
F,O,U
Cap. Cx (µF)
0.1
0.33
16/20A (mH)
0.5
0.5
= M1
= M2
CASE CODE:
FLANGE MOUNT
SNAP-IN TABS - SIDE
REAR PANEL MOUNT
=F
=U
=O
Contact PDI for attenuation numbers
SCHEMATICS
1
L mH
L
L'
R
CX
Cy
L
G'
Cy
N
N'
G
L mH
Lg
2
L
R
N
G
Lg
L mH
L'
Cy
L
G'
Cy
N'
L mH
3
L mH
L
L'
Cy
R
L CX
G'
Cy
N
N'
L mH
G
Lg
MEDICAL
SCHEMATICS
1M
L
L mH
L'
R
CX
L
N
N'
G
L mH
G'
Lg
2M
L
R
L mH
L'
L CX
N
N'
G
L mH
G'
Lg
Non-Medical ApplicationsO
Insertion loss in dB (50 Ohm circuit)
Attenuation
Code
A
B
C
Comm. Mode(L-G) in MHz
.15 .5 1 5 10 30
17 22 26 43 51 43
17 23 28 47 57 45
17 22 26 43 51 43
Diff. Mode(L-L) in MHz
.15 .5 1 5 10 30
8 18 24 45 43 35
8 18 23 51 54 34
18 28 33 46 53 35
OThis table applies to schematic 1 only.
Visit our website or contact PDI for other schematic attenuation numbers.
Medical Applications"
Insertion loss in dB (50 Ohm circuit)
Attenuation
Code
M1
M2
Comm. Mode(L-G) in MHz
.15 .5 1 5 10 30
16 21 22 24 25 20
16 20 22 24 25 20
Diff. Mode(L-L) in MHz
.15 .5 1 5 10 30
8 18 25 42 43 30
17 28 33 41 40 31
"This table applies to schematic 1M only.
Visit our website or contact PDI for other schematic attenuation numbers.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
14