English
Language : 

HGN-375 Datasheet, PDF (1/2 Pages) PowerDynamics, Inc – IEC 60320 INLET SOCKET WITH SWITCH, SINGLE AND DOUBLE FUSE HOLDER, FLANGE MOUNT
HGN-375 IEC 60320 INLET SOCKET WITH SWITCH, SINGLE AND DOUBLE FUSE HOLDER,
FLANGE MOUNT
MECHANICAL DIMENSIONS (Unit: mm)
52.0
67.0
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
33.5
O
40.0+- 0.2
0.8 TYP.
FEATURES
The HGN-375 protects electronic equipment from common
and differential mode line interference in the range of
10KHz up to 30MHz. This “combi-unit” is equipped with
IEC connector, fuse holder for one or two 5 x 20 mm fuses,
2 pole on/off switch and fully enclosed metal housing.
These filters are also available for Medical equipment
with low leakage current. HGN-375 series filters are high
performance filters and have been designed to bring various
medical equipments into compliance with EN55011 and
FCC Part 15J, Class B conducted emissions limits.
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 4A, 6A, 10A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
* Medical application
60.5
28.5
6.30 TYP.
57.5
45.0
6.0
40.0+- 0.2
29.5
4x R0.5
61.5
2x M3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com • www.powerdynamics.com
79