English
Language : 

ACE Datasheet, PDF (2/5 Pages) Powerbox – 3 0 0 - 9 0 0 WAT T S - A C / D C M O D U L A R O U T P U T
ACE Series
300-900 WATTS - AC/DC MODULAR OUTPUT
150W SUITABLE SINGLE OUTPUT
50W SUITABLE SINGLE OUTPUT 75W DUAL OUTPUT
ITEM
CODE
A B C D E F G H J K L M N P R Y*7 W*7 Z*7 9*7
Number of slots used
1111111111 1 1 1 1 1 1111
Voltage
2 3.3 5 7.5 12 15 18 24 34 48 3.3 5 12 15 24 ±5 ±12 ±15 ±24
Minimum current
0000000000 0 0 0 0 0 0000
Current1(A)
26 26 26 18 13 10 8.5 6.5 4.5 3.2 10 10 5 4 2.5 3 3.2 2.5 1.6
Current2(A)
— — — — — — — — — — — — — — — 7 4.2 3.5 2.5
Peak current(A)*1
— — — — 14 12 10 8 5.5 4 — — — — — 5 4 — —
Line regulation(mV)max
20 20 20 36 48 60 72 96 120 192 20 20 48 60 96 20 48 60 60
Load regulation1(mV)max*5
40 40 40 100 100 120 120 150 180 300 40 40 100 120 150 250 600 600 600
Load regulation2(mV)max*6
— — — — — — — — — — — — — — — 500 750 750 750
Ripple
(mVp-p)max
0 to +50°C*2 80 80 80 120 120 120 120 120 120 150 80 80 120 120 120 80 120 120 120
-20 to 0°C*2 140 140 140 160 160 160 160 160 160 300 140 140 160 160 160 140 160 160 160
Ripple Noise
(mVp-p)max
0 to +50°C*2 120 120 120 150 150 150 150 150 150 350 120 120 150 150 150 120 150 150 150
-20 to 0°C*2 160 160 160 180 180 180 180 180 180 400 160 160 180 180 180 160 180 180 180
Temp Coeff. (mV)max 0 to +50°C 50 50 50 90 120 150 180 240 300 480 50 50 120 150 240 50 120 150 150
Drift (mV)max*6
20 20 20 36 48 60 72 96 120 192 20 20 48 60 96 20 48 60 60
Output voltage setting(V)
2.00- 3.25- 4.99- 7.20- 11.5- 14.4- 17.3- 23.0- 33.0- 46.0- 3.25- 4.99- 11.5- 14.4- 23.0- 4.99- 11.5- 14.5- 23.0-
2.20 3.45 5.30 7.80 12.5 15.6 18.7 25.0 35.0 50.0 3.45 5.30 12.5 15.6 25.0 5.30 12.5 15.6 25.0
Output voltage adjustment
range(V)*4
1.60- 2.60- 4.00- 6.00- 9.00- 13.2- 16.5- 19.2- 27.2- 38.4- 2.60- 4.00- 9.00- 13.2- 19.2- 4.99- 9.60- 13.2- 19.2-
2.60 3.60 5.50 8.20 13.2 16.5 19.2 26.4 37.4 52.8 3.60 5.50 13.2 16.5 26.4 6.00 13.2 16.5 26.4
Overcurrent protection(A)
Works over 105% min of rated current or 101% min of peak current. Automatic recovery
Overvoltage protection(V)
3.00-
4.80
4.00-
5.25
Works
at
115%-140%
of
rated
voltage
4.00- Works at 115%-140% of 6.90- 13.8- 17.2- 27.6-
5.25 rated voltage
8.40 16.8 21.0 33.6
Function
Remote sensing, remote ON/OFF, alarm(LV)
Remote ON/OFF, alarm(LV)
300W SUITABLE SINGLE OUTPUT
100W SUITABLE DUAL OUTPUT
150W DUAL
OUTPUT
*
ITEM
CODE
2A 2B 2C 2D 2E 2F 2G 2H 2J 2K
S
T
U
W ZI
Number of slots used
Voltage
2222222222
1
1
1
1
11
2 3.3 5 7.5 12 15 18 24 34 48 V1; 5 V1; 5 V1; 5 V1; 12 V1; 5 V1; 24 ±12 ±15
Minimum current
00000000000000000 0
Current1(A)
60 60 60 40 25 20 17 14 10 7 10 5 10 4.2 10 2.1 6.4 5.5
Current2(A)
———————————————— 8 7
Peak current(A)*1
— — — — 34 27 23 20 14 10 — — — — — — 10 8
Line regulation(mV)max
20 20 20 36 48 60 72 96 120 192 20 20 20 48 20 96 48 60
Load regulation1(mV)max*5
40 40 40 100 100 120 120 150 180 300 40 40 40 100 40 150 600 600
Load regulation2(mV)max*6
— — — — — — — — — — — — — — — — 750 750
Ripple
(mVp-p)max
0 to +50°C*2 80 80 80 120 120 120 120 120 120 150 80 80 80 120 80 120 140 140
-20 to 0°C*2 140 140 140 160 160 160 160 160 160 300 140 140 140 160 140 160 200 200
Ripple Noise
0 to +50°C*2 120 120 120 150 150 150 150 150 150 350 120 120 120 150 120 150 230 230
(mVp-p)max
-20 to 0°C*2 160 160 160 180 180 180 180 180 180 400 160 160 160 180 160 160 350 350
Temp Coeff. (mV)max 0 to +50°C 50 50 50 90 120 150 180 240 300 480 50 50 50 120 50 240 120 150
Drift (mV)max*6
20 20 20 36 48 60 72 96 120 192 20 20 20 48 20 96 48 60
Output voltage setting(V)
2.00- 3.25- 4.99- 7.20- 11.5- 14.4- 17.3- 23.0- 33.0- 46.0- 4.99- 4.99- 4.99- 11.5- 4.99- 23.0- 11.5-
14.4-15.6
2.20 3.45 5.30 7.80 12.5 15.6 18.7 25.0 35.0 50.0 5.30 5.30 5.30 12.5 5.30 25.0 12.5
Output voltage adjustment
range(V)*4
1.60- 2.60- 4.00- 6.00- 9.00- 13.2- 16.5- 19.2- 27.2- 38.4- 4.99- 3.00- 4.99- 7.50- 4.99- 15.0- 9.60-
13.2-16.5
2.60 3.60 5.50 8.20 13.2 16.5 19.2 26.4 37.4 52.8 5.50 5.50 5.50 13.2 5.50 26.4 13.2
Overcurrent protection(A)
Works over 105% min of rated current or 101% min of peak current. Automatic recovery
Overvoltage protection(V)
Function
3.00- 4.00-
Works at 115%-140% of rated voltage
4.80 5.25
Remote sensing, remote ON/OFF, alarm(LV)
Remote ON/OFF
Same as W, Z —
*1 Operating condition of peak current : Peak current is less than 10sec., duty is less than 35% and average current is less than
rated current. (rated current2 at Module W, Z, 9, Q and V)
*2 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM101). Ripple and Ripple Noise is
measured by using measuring board with capacitor of 22mF within 150mm from output terminal.
*3 Drift is changed in DC output for an eight hour period after half-hour warm-up at 25C, with the input voltage held constant at
the rated input/output.
*4 When the output voltage of module A is used less than 2.0V, keep minimum output current 2.6A.
*5 It is a value from 0 to rated output current1. The current on non-measurement side is fixed.
*6 It is a value from 0 to rated output current2. The current on non-measurement side is fixed.
*7 The sum of +power and -power must be less than output power(Y:50W, W:76.8W, Z:75W, 9:76.8W, Q:153.6W, V:165W).
*8 Ratings of V2 can draw up to 50% of rated current at the time of 0A in load of V1.(Only module S,T,U. refer to instruction manual
4.2 for details.)
* Each output of module Y-Z, 9, Q and V is a ground common type (not isolated),each output ofmodule S,T and U is isolated.
= For ACE300F,450F and 650F , input and output terminals can be set at the same side if Input module (code:I) is installed
instead of the most left module.
* Modules which can correspond to medical electrical equipment (UL2601-1, EN60601-1) are all modules except module S, T
and U. Refer to instruction manual 7. for details.
Doc. No. PBC9 Rev.D 10-8-12
Powering Progress – www.powerbox.com.au
77