English
Language : 

V24A48C500BL Datasheet, PDF (1/1 Pages) Powerbox – 50 - 400W PCB MOUNTING COMPONENTS
24V 2nd Gen
50-400W PCB MOUNTING COMPONENTS
Features
• Input Voltage: 18-36Vdc
• Output Voltage: 2-48Vdc
• Output Power (per module):Maxi: 400W Micro:
100W
• Efficiency: Up to 90%
• Agency Approvals: UL, CSA, TUV, VDE, BABT,CE
Marked, C-Tick
Specifications
Units
Notes
Set point accuracy
Line regulation
Load regulation
Temperature regulation
Ripple and noise, p-p
Remote sense
compensation
Overvoltage set point
±1% Vout nom.
±0.02% Vout nom.
±0.02% Vout nom.
±0.002% Vout/°C
100mV
0.5 Volts
Nominal input; full
load; 25oC
Low line to high line;
full load
No load to full load;
nominal input
-20oC to 100oC
Full load, 20 MHz
bandwidth
115% Vout nom.
Current limit
115% out max.
Vout 95% of nominal
Efficiency: 5V out
24Vout
Programming range
Short circuit current
Isolation voltage
83%
88%
10-110% Vout nom.
115% out max.
3000Vrms
Nominal input; 80%
load; 25oC
Nominal input; 80%
load; 25oC
Output voltage
<250mV
Input to Output
(typical unless otherwise noted)
STANDARDS AND APPROVALS
C-Tick
AS/NZS CISPR11 Group 1 Class A
Selection Table
OUTPUT VOLTAGE (VDC)
3.3V
5V
12V
15V
24V
28V
48V
OUTPUT POWER (W)
MAXI
MINI
MICRO
264
150
75/50
400
200
100/50
400
200
100/50
400
200
100/50
400
200
100/50
400
200
100/50
400
200
100/50
Product Grade Specifications
E
C
T
H
M
Operating Temp. (°C) -10 to 100 -20 to 100 -40 to 100 -40 to 100 -55 to 100
Storage Temp. (°C) -20 to 125 -40 to 125 -40 to 125 -55 to 125 -65 to 125
Temp. Cycling
none none none 24 hours 24 hours
(°C)
(-55 to 125) (-65 to 125)
Burn-In
none none none 12 hours 24 hours
Low Temp.Test (°C) none none none -40°C
-55°C
High Temp.Test (°C) none none none 100°C 100°C
Final Test Data
none none none
Mechanical Drawings refer to page 237-238
*Other O/P voltage consult sales
Part Numbering
24
Your dependable power partner – www.powerbox.com.au