English
Language : 

SM700 Datasheet, PDF (1/2 Pages) Powerbox – 600-700 WATTS PROGRAMMABLE DC SUPPLY
SM 700 Series
6 0 0 - 7 0 0 WAT T S P R O G R A M M A B L E D C S U P P LY
Features
• Constant voltage and constant current operation
• Parallel operation master/slave
• EMC standard EN61204-3
• Excellent response to load change
• CE marked
• Optional ethernet, RS232, IEEE 488 programming
• Natural convectional cooling
Specifications
INPUT
Input voltage
90-132/185-265VAC
Frequency
48Hz–62Hz
Inrush current
6.5A @ 230Vac, 30A @ 110Vac.
Insulation
Input – Output: 3750V rms (8mm creepage)
Input – Case: 2500V rms
Output – Case: 600VDC
OUTPUT
Output voltage
See table
Output voltage adjustment 0%–100%
Output current
See table
Output current adjustment 0%–100%
Resolution
Overvoltage protection
0.03% voltage and current control with 10 turn
potentiometers.
SM1540-D: 0-17V, SM7020-D: 0-80V,
SM3004-D: 0-350V.
Overload protection
Yes
Short circuit protection
Yes
Temperature coefficient CV: 5x10-5 per °C, CC: 1x10-4 per °C.
Load regulation
0%–100% load see table.
Line regulation
Line ±10% – see table.
Ripple & Noise
See table.
Stability
Output impedance
(0-100kHz)
Recovery time
CV: 3x10-4, CC: 1x10-3
SM1540: <40mΩ, SM7020: <60mΩ,
SM3004: < 700mΩ.
(50%–100% load step): 100µS; 150µS for SM
7020.
Remote sense
2V max. per lead compensation.
OPERATING
Efficiency
87%–89% .
Switching frequency
100kHz
Thermal protection
Programming
Programming speed
Master/Slave operation
Metering
Yes
Analogue Programming of voltage and current by
0-5V.
See table
Parallel and series operation with equal current
and voltage sharing. In this way two or more SM-
units can together be used as one high power unit.
Voltage and current of the units is controlled by the
master (by potentiometers or by programming).
Series operation up to 600V
Digital meters standard
Indicators
CV/CC mode, OVP triggered LEDs
MTBF
500,000hrs
BATTERY CHARGING
The CV/CC regulated power supplies are suitable for battery charging.
Ask for the special datasheet “BATTERY CHARGING WITH SM-series POWER
SUPPLIES”. This datasheet contains information about protective measures
against accidental battery reversing.
ENVIRONMENTAL
Operating temperature
Humidity
Storage temperature
-20°C to 50°C
95% RH max, non condensing, up to 40 °C.
75% RH max, non condensing, up to 50 °C.
-40°C to 85°C
Cooling
Natural convection
STANDARDS AND APPROVALS
Safety standards
EN60950 / EN61010
EMC standards
EN61204-3, EN61000-6-2
EMI standards
EN61000-6-3 (EN55022B)
MECHANICAL
Mounting
Bench or 19" rack mounting
464