English
Language : 

SM3000 Datasheet, PDF (1/2 Pages) Powerbox – 3000 WATTS PROGRAMMABLE DC SUPPLY
SM 3000 Series
3 0 0 0 WAT T S P R O G R A M M A B L E D C S U P P LY
Features
• Constant voltage and constant current operation
• Parallel operation master/slave
• EMC standard EN61204-3
• CE marked
• Optional ethernet, RS232, IEEE 488 programming
• IEEE 488 programming option
• Ethernet, RS232 option
Specifications
INPUT
Input voltage
342-457Vac 3 phase.
Frequency
48Hz–62Hz
Inrush current
5.8A @ 400Vac input.
Isolation
I/P to O/P: 3750V rms (8mm creepage),
I/P – Case: 2500V rms, O/P – Case: 600VDC
OUTPUT
Output voltage
See table.
Output voltage adjustment 0%–100%
Output current
See table.
Output current adjustment 0%–100%
Resolution
Overvoltage protection
0.03% voltage and current control with 10 turn
potentiometers.
Yes. Trip range user adjustable 0%–115% of V
max.
Overload protection
Yes
Short Circuit protection Yes
Temperature coefficient
CV: 10x10-6 to 35x10-6 / °C,
CC: 20x10-6 to 60x10-6 / °C.
Load regulation
0%–100% load see table
Line regulation
Line ±10% – see table
Ripple & Noise
See table
Stability
CV: 2.10-5 to 4.10-5, CC: 3.10-5 to 10.10-5
Output impedance
(0-100kHz)
SM15-200D: < 25mΩ, SM30-100D: < 20mΩ
SM45-70D: < 60mΩ, SM70-45D: < 60mΩ
SM120-25D: < 150mΩ, SM300-10D: < 800mΩ.
Recovery time
(50%–100% load step): 100µS
Remote sense
2V max. per lead compensation (SM 3004 has no
remote sense)
OPERATING
Efficiency
87%–91%
Switching frequency
100kHz
Thermal protection
Yes
Programming
Analogue Programming of voltage and current by
0-5V. IEEE488 programming with external
interface controller PSC44M
Programming speed
See table
Master/Slave operation
Parallel and series operation with equal current
and voltage sharing. In this way two or more SM-
units can together be used as one high power
unit. Voltage and current of the units is controlled
by the master (by potentiometers or by
programming). Series operation up to 600V
Metering
Digital meters standard
Indicators
CV/CC mode, OVP triggered LEDs
BATTERY CHARGING
The CV/CC regulated power supplies are very suitable for battery charging.
Ask for the special datasheet “BATTERY CHARGING WITH SM-series POWER
SUPPLIES”. This datasheet contains information about protective measures
against accidental battery reversing.
ENVIRONMENTAL
Operating temperature
-20°C to 50°C
Cooling
Low noise blower, fan speed adapts to
temperature of internal heatsink. (from left to
right).
STANDARDS AND APPROVALS
Safety standards
EN60950 / EN61010
EMC standards
EN61204-3, EN61000-6-2
EMI standards
EN61000-6-3 (EN55022B)
MECHANICAL
Mounting
Bench or 19" rack mounting
468