English
Language : 

SM1500 Datasheet, PDF (1/2 Pages) Powerbox – 1500 WATTS PROGRAMMABLE DC SUPPLY
SM 1500 Series
1 5 0 0 WAT T S P R O G R A M M A B L E D C S U P P LY
Features
• Constant voltage and constant current operation
• Parallel operation master/slave
• EMC standard EN61204-3
• CE marked
• Optional ethernet, RS232, IEEE 488 programming
• Designed for long life at full power
Specifications
INPUT
Input voltage
90-265Vac
Frequency
48Hz–62Hz
Inrush current
27A @ 115Vac, 22A @ 230Vac.
Power factor
0.99
Isolation
I/P to O/P: 3.75kVrms (1min.), Creepage: 8mm
I/P to Case: 2.5kVrms, O/P to Case: 600Vdc
OUTPUT
Output voltage
See table.
Output voltage adjustment 0%–100%
Output current
See table.
Output current adjustment 0%–100%
Resolution
0.03% voltage and current control with 10 turn
potentiometers.
Overload protection
Yes
Short circuit protection Yes
Temperature coefficient CV: 35x10-6 per °C, CC: 60x10-6 per °C
Load regulation
0%–100% load – see table
Line regulation
Line ±10% – see table
Ripple & Noise
See table
Stability
CV: 6x10-5, CC: 9x10-5
Output impedance
(0-1kHz; 1-100kHz)
SM15-100: < 1.3mΩ; < 25mΩ
SM35-45: < 1.7mΩ; < 30mΩ
SM52-30: < 3.5mΩ; < 30mΩ
SM52-AR-60: < 3.3mΩ; < 40mΩ
SM70-20: < 7.5mΩ; < 30mΩ
SM120-13: < 63mΩ; < 0.6Ω
SM300-5: < 125mΩ; < 1Ω
SM400-AR-8: < 83mΩ; < 1.3Ω
Recovery time
(50%–100% load step): 100µS.
Remote sense
2V max. per lead compensation.
OPERATING
Efficiency
87%–91%.
Switching frequency
100kHz.
Thermal protection
Yes.
Programming
Analogue Programming of voltage and current by
0-5V.
Programming speed
See table.
Master/Slave operation
Parallel and series operation with equal current
and voltage sharing. In this way two or more SM-
units can together be used as one high power
unit. Voltage and current of the units is controlled
by the master (by potentiometers or by
programming). Series operation up to 600V.
Metering
Digital meters standard.
Indicators
CV/CC mode, OVP triggered LEDs.
BATTERY CHARGING
The CV/CC regulated power supplies are very suitable for battery charging.
Ask for the special datasheet “BATTERY CHARGING WITH SM-series POWER
SUPPLIES”. This datasheet contains information about protective measures
against accidental battery reversing.
ENVIRONMENTAL
Operating temperature
-20°C to 50°C.
Cooling
Low noise blower, fan speed adapts to
temperature of internal heatsink. (from left to
right).
STANDARDS AND APPROVALS
Safety standards
EN60950 / EN61010
EMC standards
EN61204-3, EN61000-6-2
EMI standards
EN61000-6-3 (EN55022B)
MECHANICAL
Mounting
Bench or 19" rack mounting
466