English
Language : 

PUP120 Datasheet, PDF (1/2 Pages) Powerbox – 120 WATTS SINGLE OUTPUT AC/DC GENERAL
PUP 120 Series
120 WATTS SINGLE OUTPUT AC/DC GENERAL
Features
• High Efficiency.
• Low ripple and noise.
• Short circuit protection.
• Overvoltage protection.
• Over power protection.
• Over temperature protection.
• 100% burn-in at full rated load.
• Standby consumption less than 0.75W.
• MEPS compliance.
Specifications
INPUT
Input voltage
Frequency
Input current
Leakage current
Isolation
Inrush current
OUTPUT
Output voltage
Output current
Ripple & noise
Line regulation
Load regulation
Transient response
Overvoltage protection
Overcurrent protection
Temperature coefficient
Holdup time
90-264Vac.
47Hz–63Hz
1.60A @ 115V, 0.8A @ 230V
0.4mA max. @ 115Vac. 60Hz.
0.8mA max. @ 230Vac. 50Hz.
Input – Output: 3000Vac
Input – Ground: 1500Vac
Output – Ground: 500Vac
60A @ 115V, 120A @ 230V
See table
See table
1% peak to peak
±0.5% maximum at full load.
See table
Max. deviation 4% recovering to 1% within
500µs after 25% load charge
Provided on V1 only. Set at 110%–140% of
nominal.
All outputs protected for short circuit conditions
All outputs ±0.04% per °C.
Typically 15ms at 110VAC.
OPERATING
MTBF
100,000 hrs @ 25°C.
Efficiency
80-86% minimum.
Power factor
0.98 typical at 115Vac.
ENVIRONMENTAL
Operating temperature
0°C to 40°C.
Storage temperature
-20°C to 85°C
Relative humidity
10%–95% non-condensing
STANDARDS AND APPROVALS
Safety
C-Tick
UL60950-1, CSA C22.2 No. 60950, Nemko
EN60950: 2000.
AS/NZS CISPR11 Group 1 Class A
EMC standards
MECHANICAL
EN55024, EN55022-B, FCC-B, VCCI-B, EN61000-3-
2, -3, EN61000-4-2, -3, -4, -5, -6, -8, -11.
Dimensions
167x65x37mm
Weight
0.62kgs approx.