PSE100 Datasheet, PDF (1/2 Pages) Powerbox – 60 - 100 WATTS DC/DC SINGLE OUTPUT
PSE100 Series
60-100 WATTS DC/DC SINGLE OUTPUT
Features
• Under voltage logic alarm.
• Conformally coating, tropic.
• Reverse input voltage protection.
• High efficiency.
• Fully encapsulated, meets IP30 standard.
• Convectional cooled.
Specifications
INPUT
Voltage
See table
Isolation
Input – Output: 2kVdc (Input code A, B)
Input – Output: 2.5kVac / 4kVdc (Input code C/ D)
Input – Case: 2kVdc (Input code A, B)
Input – Case: 2.5kVac / 4kVdc (Input – code C/ D)
Output – Case: 2kVdc
Reverse voltage protection Yes.
OUTPUT
Voltage
See table.
Current
See table.
Source regulation
0.2%.
Load regulation
0.2% (0-100% load)
Output ripple (100kHz)
10mV p-p (typical)
Voltage adjustment
90% - 110%.
Current limit protection 105%.
Under voltage logic alarm 90% of nominal output.
Soft start
Yes.
Start-up time
1s.
Hold-up time
2-10ms
Efficiency
80-88%
ENVIRONMENTAL
Operating temperature
Temperature coefficient
-25°C to +70°C (100% load, O/P > 10V). -25°C to
+55°C (100% load, O/P < 10V).
0.02% / °C.
Storage temperature
Conformal coating
MECHANICAL
-40°C to 85°C.
Conformal coated to withstand non-condensing
tropical environment RH 95%
Mechanical dimensions 3U x 8TE x 167mm
Weight
0.85kg
GENERAL
Cooling
Optional features
STANDARDS
Safety
EMI standards
C-Tick
EMC standards
Convectional cooling.
-Overvoltage protection, option A. The output
voltage is limited to 15% nominal output voltage. A
thyristor short- circuit the output.
-Undervoltage alarm with relay, option B. The
logic alarm output is replaced with Relay with
selectable alarm logic NO or NC.
-Built in series diode, option C. A series diode
on the output, when output is connected in parallel
with other power supplies to achieve redundancy.
Output power might be derated.
-Remote sense, option S. The voltage sensing can
be put at the load to compensate for voltage drop.
This is standard feature on 5V output.
-Inrush current limit with NTC, option H. Only for C
-input code. Reduce the inrush current during the
start up. The input voltage range will be affected.
- 2.5kVac isolation input/case, option E1. On
A and B inputs. The emission level increase to level A.
- 2.5kVac isolation output/case, option E2. The
emission level will increase to level A.
-Train input, option T. Input voltage range
according to train Standard EN50155 and IEC 60751.
- Euro panel, option L 8TE for PSE 100, 10TE for 5V
output with extra cooler.
- Wall mounting panels, option N. Wall
mounting panel with connector holder The female
connector has to be chosen.
- H15 screw type female, H15-S
- H15 fast-on 6.3mm female, H15-T
- Din rail TS35 clips, option Q.
IEC60950-1: 2001
EN55011/EN55022 class B, IEC/EN61000-6-2,
AS/NZS CISPR11: 2002 Group1 Class A
EN61000-6-2, EN/IEC61000-4-4, EN61000-4-5
Your dependable power partner – www.powerbox.com.au
411