English
Language : 

PSC600 Datasheet, PDF (1/2 Pages) Powerbox – 250 - 800 WATTS DC/DC SINGLE OUTPUT
PSC 600 Series
250-800WATTS DC/DC SINGLE OUTPUT
Features
• Single outputs from 5Vdc to 125Vdc.
• Conformal coating.
• Under voltage alarm.
• High efficiency.
• Operating temperature range -25°C to +70°C with
no derating.
• Fully encapsulated, IP30 as standard.
• Convection cooled.
Specifications
INPUT
Voltage
See Table
Isolation
Input - Output: 2.5kVac / 4kVdc
Input – Case: 2.5kVac / 4kVdc
Output– Case, all outputs: 2kVdc
Reverse input voltage
protection
Parallel diode (Input code: 24, 48)
Series diode (Input code: 110, 220)
OUTPUT
Voltage
See table.
Current
See table.
Source regulation
0.2%.
Load regulation
0.2%.
Output ripple (50kHz)
20mV p-p typ.
Input ripple attenuation on 150:1
output 50 to 400Hz
Voltage adjustment
90% - 110%.
Current limit protection 105%.
Overvoltage protection
115%.
Under voltage alarm
90% of nominal output.
Remote sense
Option S.
Soft start
Yes.
Start-up time
1s
Hold-up time
2-25ms
Efficiency
80 - 93%
Switching Frequency
50 kHz
Selection Table
T-input range for mobile application
Uin 0.1s-S2
Continuous range
Code
14.4-33.6V
16.8-30V
24T
21.6-50.4V
25.2-45V
36T
28.8-67.2V
33.6-60V
48T
43.2-110.8V
50.4-90V
72T
66-154V
77-137.5V
110T
The total output power can be derated on a T-range compared with the above
output rating table. Input according to EN50155:2001 and IEC90571:1998
ENVIRONMENTAL
Operating temperature
-25°C to 70°C
(100% load, single output >10Vdc).
-25°C to +55°C
(100% load, single output <10Vdc).
Temperature coefficient 0.02%/°C.
Storage temperature
-40°C to 85°C.
GENERAL
Cooling
Optional Features
STANDARDS
Convectional cooling.
-Built in series diode – C.
-Remote sense – S.
-Inrush current limit. On input code 24 and 48
the inrush limit circuit is optional. This option
affects the input voltage range. The circuit is
always active thus acting at voltage dips below
the stop level > 10ms.
-2.5kVac isolation input/case –E1.On the 24
and 48 inputs.The emission level increases to level
A.
-2.5kVac isolation output/case
-E2.The emission level increases to level A.
-Euro panel –L,10TE OR 14TE
-Wall mounting panels –N. Included H15
connector holder. Standard female Connector
H15-T. To mount on a DIN TS-35 rail, we can
supply optional DIN rail clips.
-Wider input range The PSC600 series can be
supplied with wide input range to meet train or
mobile application demands.
Safety
IEC60950
EMI standards
EN55011/EN55022 class B, EN61000-6-3
C-Tick
AS/NZS CISPR11: 2002 Group1 Class A
EMC standards
EN61000-6-2, EN/IEC61000-4-4, EN61000-4-5
Note:
For mechanical dimensions and mounting options please contact Powerbox for
further details.
422