PSC04 SERIES - TELECOM RECTIFIER SYSTEMS
FEATURES
• 1000W - 4000W
• Configurable Battery Charging System
• 1U 19" Rack Mounting
• Network Monitoring
• N+1 Operation
• System Monitoring
• Load & Battery MCBs
• Battery LVD
• Customized shelf configurations available
• Fully Featured Telecom Grade Rectifier
SPECIFICATIONS
INPUT
AC input
Frequency range
Power factor
Termination
OUTPUT
Nominal voltage
Output power
Polarity
DC DISTRIBUTION
Load
Battery
Breaker fail detection
DC Terminals
Low voltage disconnect
ENVIRONMENTAL
Ambient Temperature
Storage Temperature
Humidity
Altitude
MECHANICAL
Dimensions
Weight
Shipping Dimensions
Shipping Weight
240V AC (90-300V) Single phase
45-66 Hz
>0.99 full load
PSC04 V1: 1 phase, LNE 10mm², tunnel terminals
PSC04 V2: 1 phase, LNE 6mm², tunnel terminals
24Vdc, 48Vdc, 60Vdc
4kW @ 48Vdc
2kW @ 24Vdc
Positive earth, (negative earth option available)
Standard Shelf configuration. (Customized
configuration available)*
Standard Shelf configuration (Customized
configuration available)*
Electronic fail detection on both load and battery
breakers
Rear connected tunnel terminals
PSC04 V1, load and battery 10mm²
PSC04 V2 load and battery 6mm²
See Shelf configuration System
-20ºC to +70ºC
-30ºC to +85ºC
5-95% RH (non-condensing)
<2,500m at full power
482.6mm (standard 19" module), 44.45mm (1U),
350mm, W,H,D
5kg (excluding rectifier modules)
540.0mm, 95.0mm, 400.0mm, W,H,D
6.0kg (excluding rectifier modules)
MONITORING & CONTROL
Display
Multi-lingual alpha numeric backlit display
Communications
LED Indicators
Serial: 1x USB port on front panel for local PC interface
TCP/IP: Ethernet interface for communication using
SNMP protocol and internal web based configurator*
Modbus: Supported via TCP/IP*
Green: Power on/monitor OK
Yellow: Non urgent alarm
Red: Urgent alarm
Audible
90dBA buzzer mappable to user defined conditions
Controls
Signal Inputs
Alarms
Alarm Contacts
3x push buttons for parameter setting or viewing on
front panel
Serial bus for rectifier control and interface to
peripheral modules
6x digital inputs
2x temperature sensors (one fitted by default)
6x alarm relays
5x of which can be mapped for customised alarm
settings
0.3A 100V volts free changeover contacts
Logging Capacity
Periodic log, 16,384 records (dependant on number of
parameters logged)
Event log, 16,384 records (dependant on number of
parameters logged)
Connections
Relay outputs, mini combicon to accept 1.5mm² wire
USB port, USB mini B
*TCP/IP and modbus options only available with SM36 supervisory module.
CONFIGURATION
& OPTIONS
Rectifiers
RM2048XE: 2.0kW modular rectifier, 230V AC input, 48V
DC output, 41.7A maximum output
RM2048HE: 2.0kW modular rectifier, 230V AC input, 48V
DC output, 41.7A maximum output
RM2048/24: 2.0kW modular rectifier, 230V AC input, 48
or 24V DC output, 41.7A maximum output
RM1860/48: 1.8kW modular rectifier, 230V AC input, 60
or 48V DC output, 30.0A maximum output
Supervisory Modules
SM35: standard monitor featuring full temperature
compensation, automated and manual battery
testing/equalisation
SM36: enhanced monitor featuring full temperature
compensation, automated and manual battery
testing/equalisation with TCP/IP
ARBP-1M
Metal rectifier blanking panel
ASM-ABM24(-24-48-60)
Battery condition monitor for 24, 48 or 60V battery
strings
ASM-AC3P
AC mains monitor
Doc. No. 1U Ultra Compact Rev.B 22-9-15