PBMPLS Datasheet, PDF (1/2 Pages) Powerbox – D C / A C S I N EWA V E I N V E R T E R
PBMPLS Series
DC/AC SINEWAVE INVERTER
FEATURES
• 500W - 7000W
• True Sinewave Output
• Massive Overload Capability
• High Efficiency Toroidal Transformer
• CCT Breaker/ Batt Isolator Switch
• Chassis and Wall mounting
SPECIFICATIONS
INPUT
Input Voltage
12V, 24V, 48V (Standard)
36V, 72V, 96V, 120V (Also available)
Voltage range
-20% to +45% of nominal..
OUTPUT
Output Voltage
230Vac ±4% (Standard)
110Vac ±4% (Option)
Output Frequency
50/60Hz ±0.1
Output Waveform
True sinewave < 4% THD.
Power factor correction
All conditions.
Crest factor
>4
Load start sensitivity
0-20W
Efficiency
94%Typically
PROTECTION
DC to AC isolation
3500V
Over-load protection
Yes.
Over-temperature protection Yes.
Short circuit protection
Battery under and
over voltage protection
Circuit breaker On/Off
Yes.
Yes.
The circuit breaker by pushing switch "UP"
the battery supply is connected to the
inverter. The circuit breaker will turn OFF
automatically if too large a load is left on
the inverter continuously. Reset the switch
after allowing approx 5mins to cool. If the
inverter shuts down due to overload,
undervolts or overvolts it can be reset by
turning the circuit breaker OFF, waiting 10
seconds (or until LED goes out). Then
turning it on again.
ENVIRONMENT
Temperature range
-10°C to 50°C
Cooling
Thermostatically controlled 2-speed fan.
STANDARDS & APPROVALS
Safety standards
AS3100, AS3000
C-tick
AS/NZS CISPR14, AS/NZS 1044
EMC standards
AS2279, EN55014
ALARMS & INDICATORS
Inverter Operation
When inverter is switched on all 3 LEDS light up for one
second for system check procedure
Power Indicator
Green LED. Flashes when in standby mode (no load
connected). When load applied LED illuminates
continuously
Undervolts/Overvolts
Red LED. In order to protect the battery the inverter will
shutdown after 5 secs if the battery voltage falls below
its limit (Undervolts) LED remains continous or exceeds
the maximum (Overvolts) LED will continue to flash.
Over temperature
Over load
Red LED, If the internal temperature exceeds safe
operating limits for more than 5 secnds, the inverter will
shut down in Over temp with this LED on continuously.
Allow 5mins for the inverter to cool and reset the unit.
Red LED, if the load demands more current than the
inverter can safely supply for more than 5 seconds, the
inverter will shutdown in Overload and this LED will flash
OPTIONAL FEATURES
CODE
ADD OPTION TO THE END OF INVERTER PART NUMBER
D
RCD fitted in place of hardware junction box of AC output.
G
MIL spec conformal coating applied to final assembly.
R
Ruggedisation for high vibration environment.
K
Automatic transfer switch 25Amp for 1000W to 1800W.
Automatic transfer switch with ON delay
KX
timer and voltage sensing module. 40Amps
for 2000W to 4000W and 65Amp for
5000W to 7000W models.
V
AC output voltage e.g. 100-120Vac.
H
Frequency 60Hz
L
"AC OK" alarm relay contact
C
Twin switched GPO
(available only on 1000W to 5000W models).
D
Twin switched RCD GPO
(available only on 1000W to 5000W models).
MECHANICAL
AC outlet
Single power outlet (500-600W models).
Single power outlet & screw terminal junction box
(1000-1800W models).
Screw terminal junction box (2000-7000W models).
Battery leads
Heavy duty low loss battery leads
Red battery positive, Black battery negative
Dimensions
500-600W: 260x160x100mm
1kw-1.8kw: 330x296x150mm
2kw-3.5kw: 370x386x180mm
4kw-7kw: 475x458x187mm
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. PBMPLS Rev.E 20-01-16